Adding a Second SAS Enclosure, Second Chain
In a dual‐controller, single SAS enclosure configuration, controller redundancy is created
using cross‐over cables (IPC) from controller ports 2 to controller ports 4. A second chain
performs the same redundancy as the IPC cross‐over cables.
Add an Enclosure
Add a new enclosure while maintaining redundancy.
1 Power on the enclosures being added. When the enclosures spin up, make sure that the
front panel enclosure and power status LEDs show normal operation.
2 Remove the two IPC cables from the Controllers, ports 2 and 4.
3 Connect: Controller A, port 2→ new Enclosure 3: top, port A.
4 Connect Enclosure 3: top, port B→ Controller B, port 4.
5 In the Storage Center System Manager, select Storage Management→ System→
Setup→ Configure Local Ports.
6 Make sure that:
Slot and slot ports are Up and the Purpose is set to back‐end.
Target Count equals the number of added drives, demonstrating that the controller
recognizes the new enclosures.
Figure 122. Adding an SC200/220 SAS Enclosure, Step 1
Dell Compellent
Controller A
Controller B
Enclosure 1
Enclosure 2
Enclosure 3
Adding SC200/220 Enclosures
191