Dell SC8000 Deployment Manual page 118

Compellent storage center
Table of Contents

Advertisement

Chapter 4 Connect the Front End
Server 1
Fabric 1
P2
Figure 93. Dual-controller with Dual-Fabric FC in Legacy Mode
See Also
Fibre Channel Zoning on page 102
Virtual Port Mode with Single-Fabric Fibre Channel
Connect virtual port mode Fibre Channel to a single fabric if only one FC is available and 
you want to protect against port or controller failure.
In this configuration, there is one fault domain because there is a single FC fabric. Each 
controller is connected to the fabric by at least two FC connections to provide port 
redundancy. If a single port fails, its virtual port fails over to another port. If a controller 
fails, the virtual ports on the failed controller move to ports on the other controller. This 
configuration is vulnerable to switch failure.
Prerequisites
Each controller must have two available FC front‐end ports.
The requirements for virtual port mode must be met.
Steps
1 Connect each server to the FC fabric.
2 Connect fault domain 1 (shown in orange) to fabric 1.
Controller A, slot 1, port 1 → Fabric 1
Controller A, slot 2, port 1 → Fabric 1
Controller B, slot 1, port 1 → Fabric 1
108
R1
R2
P1
2
1
2
1
Storage Center SC8000 Controller Deployment Guide
Server 2
Fabric 2
R4
P3
P4 R3
Controller A
Controller B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents