Quick Start Guide
Canadian Standards Association (CSA) intrinsically safe approval
(See
"Instructions for hazardous area installations (I5 and I6)" on page
I6 Certificate Number: 06 CSA 1786345
Intrinsically Safe for Class I, Div. 1, Groups A, B, C, and D
Class I, Zone 0, Ex ia IIC
Non-incendive for Class I, Div. 2, Groups A, B, C, and D
Temperature Code: T5 (see Control Drawings)
Control Drawing: 71097/1179 (with NAMUR electronics)
Ui=15 V, Ii=32 mA, Pi=0.1 W, Ci=211 nF, Li=0.06 mH
Control Drawing: 71097/1315 (with 8/16 mA electronics)
Ui=30 V, Ii=93 mA, Pi=0.65 W, Ci=12 nF, Li=0.035 mH
Single Seal
Note
A certified isolating amplifier to IEC 60947-5-6 is required for intrinsic safety if the NAMUR
electronics is used in a hazardous area installation.
A certified intrinsically safe barrier is required for intrinsic safety if the 8/16 mA electronics is
used in a hazardous area installation.

European approvals

ATEX Approvals
E1 Certificate: Sira 05ATEX1129X
Flameproof and dust proof:
ATEX Marking II 1/2 GD
Ex db IIC T6...T2 Ga/Gb
Ex tb IIIC T85 °C...T265 °C Db
(See
"Instructions specific to hazardous area installations (E1 / E7)" on page
I1 Certificate: Sira 05ATEX2130X
Intrinsic Safety for gas and dust atmospheres:
ATEX Marking
Ex ia IIC T5...T2 Ga
Ex ia IIIC T85 °C...T265 °C Da
(See
"Instructions specific to hazardous area installations (I1 / I7)" on page

International approvals

INMETRO approvals
E2 Certificate Number: TÜV 12.1285 X
Flameproof and dust proof:
Ex d IIC T6 to T2 Ga/Gb, Ex tb IIIC T85 °C to T265 °C Db
I2 Certificate Number: TÜV 12.1391 X
Intrinsically Safe for gas and dust atmospheres:
Ex ia IIC T* Ga, Ex ia IIIC T* Da (* See table in the certificate)
Ta* (* See table in the certificate)
Security parameters:
NAMUR: Ui = 15 V / Ii = 32 mA / Pi = 0,1 W / Ci = 12 nF / Li = 0,06 mH
8/16 mA: Ui = 30 V / Ii = 93 mA / Pi = 0,65 W / Ci = 12 nF / Li = 0,035 mH
Safe use special condition:
Non-metallic parts of the equipment casing can generate electrostatic charges under
extreme conditions. The equipment should only be cleaned with a damp cloth.
20