Retrieve Performance Monitoring
4
170
S
S
S
S
S
S
S
S
S
This command retrieves the performance monitoring data from the TimeSource 3100. This
data includes MTIE, TDEV, PHASE 1S, and PHASE 1 M. For current 24 hour data, MTIE,
TDEV, and PHASE 1 S data are grouped every 15 minutes. In addition, there are 7 daily
summaries of MTIE, TDEV, and PHASE1M. Each value type can be retrieved for both span
inputs A and B.
MTIE data includes the following time intervals in seconds: 1, 4, 10, 40, 100, 300, 900,
1800, 3600, 7200, 14400, 28800, and 86400.
TDEV data includes the following time intervals in seconds: 1, 2, 4, 8, 16, 32, 64, 128, 256,
512, and 1024.
PHASE1S data includes 900 seconds of phase values.
PHASE1M data includes 60 minutes of phase values.
The command format is:
RTRV-PM-EQPT:[<tid>]:SPAN-a:<ctag>::<montype>
,,,,,[<mondat>][<montm>];