Eclipse 705 Installation And Operating Manual page 36

Guided wave radar level transmitter
Table of Contents

Advertisement

PROBE SPECIFICATIONS
Description
Probe
Materials
Process seal
Probe diameter
Probe length
Blocking distance (top)
Transition Zone
(bottom)
Œ
Max
Process Temp. ¡
Min
Max Process Pressure ¡
Max Viscosity
Dielectric Range
Media coating
Description
Probe
Materials
Process seal
Probe diameter
Process Connection
Probe length
Blocking distance (top)
Transition Zone ¿ (bottom)
Max
Process Temp. ¡
Min
Max Process Pressure ¡
Max Viscosity
Dielectric Range
Mechanical load
Pull-down force
Vacuum service
Media coating
¿
Transition Zone (zone with reduced accuracy) is dielectric dependent;
It is recommended to set 4-20 mA signal outside transition zone / blocking distance.
¡
See graphs at page 39 and 40.
36
7MF-E/G/H & 7MH: hygienic single rod probe
316/316L (1.4401/1.4404), Hastelloy
also available in 316L (1.4435) stainless steel
7MF: PTFE (GRAS 21CFR177-1550 and USP <88> Class VI at 121 °C)
7MH: PEEK & 'O'-ring in Viton or EPDM (GRAS 21CFR177-1550 and USP <88> Class VI at 121 °C)
13 mm (0.50") or 6 mm (0.25")
From 30 cm to 610 cm (12" to 240") (selectable per 1 cm)
0 mm up to 910 mm (0" up to 36") - depending probe length (adjustable)
r ≥ 10: 25 mm (1")
ε
+150 °C @ 13,8 bar (+300 °F @ 200 psi) for 7MH with Viton GF 'O'-rings and 7MF
+120 °C @ 13,8 bar (+250 °F @ 200 psi) for 7MH with EPDM 'O'-rings
-40 °C @ 13,8 bar (-40 °F @ 200 psi)
13,8 bar @ +150 °C (200 psi @ +300 °F) for 7MH with Viton GF 'O'-rings and 7MF
13, 8 bar @ +120 °C (200 psi @ +250 °F) for 7MH with EPDM 'O'-rings
10.000 mPa.s (cP) – consult factory in case of agitation/turbulence
r 10-100 (depending installation conditions, down to
ε
Max error of 10 % of coated length. % Error is related to dielectric of medium, thickness of coating and
coated probe length above level.
7M1 (liquids) / 7M2 (solids): single flexible
316 SST (1.4401)
7M1/7M7: Teflon
with Viton
GFLT, Aegis PF 128 or Kalrez
®
®
7M2/7M5: Teflon
with Viton
GFLT
®
®
7M1: 5 mm (0.19")
7M2: 6 mm (0.25")
Threaded: 2" NPT or 2" BSP (G 2")
Flanged: various ANSI or EN (DIN) flanges
From 2 m (6.56') to max 22 m (72.18')
120 mm up to 910 mm (4.8" up to 36") - depending
probe length (adjustable)
305 mm (12")
7M1/7M7: +150 °C @ 27,6 bar (+300 °F @ 400 psi)
7M2/7M5: +65 °C @ 3,45 bar (+150 °F @ 50 psi)
7M1/7M7: -40 °C @ 51,7 bar (-40 °F @ 750 psi)
7M2/7M5: -40 °C @ 3,45 bar (-40 °F @ 50 psi)
7M1/7M7: 70 bar @ +20 °C (1000 psi @ +70 °F)
7M2/7M5: 3,45 bar @ +20 °C (50 psi @ +70 °F)
10.000 mPa.s (cP) – consult factory in case of
agitation/ turbulence
7M1:
r: 10-100 (depending installation conditions,
down to
ε
r ≥ 1,9)
ε
7M2:
r: 4-100
ε
7M1: 9 kg (20 lbs)
7M2: 1360 kg (3000 lbs)
Negative pressure but not hermetic seal
Max error of 10 % of coated length. % Error is related to dielectric of medium, thickness of coating and
coated probe length above level.
r = dielectric permitivity.
ε
C22 (2.4602) or AL-6XN stainless steel (UNS N08367); 7MH
®
r ≥ 1,9) – liquids
ε
7M5 (solids) /7M7 (liquids): twin flexible
FEP coated 316 SST (1.4401)
4079 (consult factory for alternatives)
®
6 mm (0.25")
300 mm to 500 mm (12" to 20")
1500 mPa.s (cP)
r: 1,9-100
ε
7M5: 1360 kg (3000 lbs)

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents