MENU: STEP BY STEP PROCEDURE: ADVANCED CONFIGURATION
Hidden diagnostic screens. Do not acces without assistance or having followed advanced training.
Screen
DispFact
1
Select
History
2
(current status)
Run time
3
xx h
History
4
Reset
HF cable
5
(select)
FidTicks
6
xxxx
FidSprd
7
X
Fid Type
8
(select)
Fid Gain
9
xxx
Window
1
xxx
Conv Fct
11
xxxx
Scl Ofst
12
xxx
Neg Ampl
13
xxx
Ifc Ampl
14
xxx
Pos Ampl
15
xxx
Signal
16
xxx
Compensate
17
(select)
DrateFct
18
Xxxx
Targ Ampl
19
Xxxx
Targ Tks
2
Xxxx
Targ Cal
21
Xxxx
OperMode
22
(select)
7xKCorr
23
xxx
ElecTemp
24
xxx C
Max Temp
25
xxx C
Min Temp
26
xxx C
SZ Hyst
27
xx.x
20
Action
Review factory parameters
Review Diagnostic messages.
Display mode.
Diagnostic display.
Superuser parameter
Diagnostic display.
Diagnostic display.
Select fiducial pulse type.
Requires superuser password.
Change gain.
None, do not adjust.
None, do not adjust.
None, do not adjust.
Enter new value.
Requires superuser password.
Enter new value.
Requires superuser password.
Enter new value.
Requires superuser password.
Diagnostic display.
Access compensation screens.
Requires superuser password.
None, do not adjust.
None, do not adjust.
None, do not adjust.
Select operating mode.
Enter a value.
Requires additional password.
None, do not adjust.
None, do not adjust.
None, do not adjust.
None, do not adjust.
Comment
Select «YES» to reveal Factory parameters; «NO» to hide.
A cumulative review of all diagnostic messages. Press the enter but-
ton twice to clear.
Shows time in hours that unit is in operation since last power on.
Select «YES» to clear «History».
Select from 1 m (3') or 3,6 m (12') remote.
Shows time of flight from electronics to fiducial pulse. Value should
remain stable within ± 10 ticks.
Value represents the variation of fiducial ticks – a value indicates that
unit is OK, a problematic spread results into an error message.
«positive» or «negative» (selection only allowed for some
probes). Consult factory before changing status.
Value represents the # of gain applied to the fiducial signal.
Factory setting.
Factory setting.
Factory setting.
Negative amplitude threshold.
Interface amplitude threshold.
Positive amplitude threshold.
Indication of signal strength.
«None» default.
The selection of «Manual» or «Auto» activates the screens 16
through 20 for 7MS/7MQ probes.
Diagnostic display if «Compsate» is on «Auto».
Shows velocity derating factor.
Diagnostic display if «Compsate» is on «Auto».
Shows amplitude of steam reference target.
Diagnostic display if «Compsate» is on «Auto».
Shows # of ticks from fiducial to steam reference target.
Diagnostic display if «Compsate» is on «Auto».
Shows the calibrated # of ticks at ambient temperature.
Selection screen if «Compsate» is on «Auto».
Select run automatically «Run», calibrate «Cal», deactivate «Off».
Distance in mm (regardless .«LvlUnits») from fiducial to user refer-
ence point. Only for 7EK (top/bottom) probe.
Shows internal housing temperature.
Diagnostic display, shows maximum internal housing temperature
recorded.
Diagnostic display, shows minimum internal housing temperature
recorded.
Safety zone Hysterisis, diagnostic factory setting