Transmitter Specifications - Eclipse 705 Installation And Operating Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

TRANSMITTER SPECIFICATIONS

FUNCTIONAL/PHYSICAL
Description
Power (at terminals)
Output
Span
Resolution
Loop Resistance
Damping
Diagnostic Alarm
User Interface
Display
Menu Language
Housing Material
Approvals
SIL ¬
Standard
(Safety Integrity Level)
electronics
Enhanced
electronics
Electrical Data
Equivalent Data
Shock/Vibration Class
Surge protection
Net weight
Cast aluminium
Stainless steel
Overall Dimensions
Foundation Fieldbus™
ITK Version
specifications
H1 Device Class
Function Blocks
Execution time
Quiescent current draw
DD/CFF files
Profibus PA
Device revision
specifications
Digital communication
protocols
Function Blocks
Execution time
Quiescent current draw
GSD files
¿
Foundation Fieldbus™ and Profibus PA™ units.
¡
For ATEX flameproof enclosure units use Ex d bushing material STYCAST 2057 FR.
¬
Not applicable for Foundation Fieldbus™ and Profibus PA™ units.
32
Specification
HART
:
®
- Weatherproof / ATEX flameproof enclosure / ATEX non sparking: 11 to 36 V DC
- ATEX Intrinsically Safe: 11 to 28,4 V DC
Foundation Fieldbus™ / Profibus PA™:
- Weatherproof / ATEX flameproof enclosure / ATEX FNICO: 9 to 32 V DC
- ATEX FISCO: 9 to 17,5 V DC
4-20 mA with HART
, 3,8 mA to 20,5 mA useable (meets NAMUR NE 43) – HART 6,
®
Foundation Fieldbus™ H1 or Profibus PA™ H1
15 cm to 22 m (6" to 72.18') depending on selected probe
Analog: 0,01 mA
Display: 0,1 (cm or inch)
630 Ω @ 20,5 mA - 24 V DC
Adjustable 0-10 s
Adjustable 3,6 mA, 22 mA, HOLD last output
HART
communicator, AMS
or PACTware™, Foundation Fieldbus™, Profibus PA™
®
®
and/or 3-button keypad
2-line x 8-character LCD
English/Spanish/French/German (Foundation Fieldbus™, Profibus PA™: English)
IP 66/Aluminium A356T6 (< 0.20 % copper) or stainless steel
ATEX II 3 (1) G EEx nA [ia] IIC T6, non sparking (probe can be used in flammable liquids)
ATEX II 3 (1) G EEx nA [nL][ia] IIC T6, FNICO – non incendive ¿ (probe can be used in
flammable liquids)
ATEX II 1 G Ex ia IIC T4 Ga, intrinsically safe
ATEX II 1 G Ex ia IIC T4 Ga, FISCO – intrinsically safe ¿
ATEX II 1/2 G Ex d[ia Ga] IIC T6 Gb ¡
ATEX II 1/2 D Ex t[ia Da] IIIC T85°C Db IP66 ¡
IEC Ex d[ia Ga] C T6 Gb
IEC Ex t[ia Da] IIIC T85°C Db IP66
IEC Ex ia IIC T4 Ga, intrinsically safe
IEC Ex ia IIC T4 Ga, FISCO – intrinsically safe ¿
IEC Ex ic[ia Ga] C T4 Gc
EN 12952-11 and EN 12953-9 CE approved for steam drums as primary level safety
device
TÜV – WHG § 63, VLAREM
LRS – Lloyds Register of Shipping (marine applications)
Other approvals are available, consult factory for more details
Functional safety to SIL 1 as 1oo1 / SIL 2 as 1oo2 in accordance to IEC 61508 – SFF of
84,5 %
Functional safety to SIL 2 as 1oo1 in accordance to IEC 61508 – SFF of 91 %
Certified for use in SIL 3 loops.
Ui = 28,4 V, li = 124 mA, Pi = 0,84 W (HART
Ui = 17,5 V, li = 380 mA, Pi = 5,32 W (Foundation Fieldbus™ / Profibus PA™)
Ci = 2,2 nF, Li = 3 µH (HART
®
Ci = 3 nF, Li = 3 µH (Foundation Fieldbus™ / Profibus PA™)
ANSI/ISA-S71.03 Class SA1 (Shock), ANSI/ISA-S71.03 Class VC2 (Vibration)
Meets CE EN 61326 (1000V)
2,7 kg (6.0 lbs) – transmitter head / electronics only
5,7 kg (12.6 lbs) – transmitter head / electronics only
H 214 mm (8.43") x W 111 mm (4.38") x D 188 mm (7.40")
5.0
Link Master (LAS) – selectable ON/OFF
1 x RB, 4 x AI, 1 x TB and 1 x PID
AI = 15 ms, PID = 40 ms
15 mA
Available at www.fieldbus.org
0x01
Version 3.0 MBP (31.25 kbits/sec)
1 x PB, 4 x Al blocks, 1 x TB
15 ms
15 mA
Available at www.profibus.com
5.17-7
)
®
)

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents