K.6 Recommended rinsing times
Recommended rinsing times in measurements with high concentrations and longer
measurements:
Rinse instrument: Expose probe to fresh air and start fl ue gas analysis
Parameter
Concentration [ppm]
CO
50
100
200
500
1000
2000
4000
8000
COlow
10
20
50
100
200
500
NO
50
100
200
500
1000
2000
3000
NOlow
10
20
50
100
200
300
NO2
10
20
50
100
200
500
SO2
50
100
200
500
1000
2000
5000
Measurement duration [min]
60
30
20
10
10
10
5
5
60
30
20
10
10
10
60
45
30
20
10
10
5
60
45
30
20
10
10
60
45
30
20
10
10
60
30
20
15
10
10
5
Testo-Direct
www.
Recommended rinsing time [min]
5
5
10
10
15
20
30
60
5
5
10
10
15
20
5
5
5
10
10
20
30
5
5
5
10
10
20
5
5
5
10
10
20
5
5
10
10
10
20
40