Cabling Procedure - AudioCodes Mediant 3000 Hardware Installation Manual

Media gateway & enterprise session border controller
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

E1/T1 Number
(26 to 42)
RTM-8410 in Slot #2
39
40
41
42
5.3.1.4

Cabling Procedure

The procedure below describes how to cable the E1/T1 trunks
To connect the E1/T1 trunk interfaces:
1.
Prepare a SCSI cable of suitable length to connect between RTM-8410 housed in Slot
#2 and the PBX/PSTN switch. The connector at the RTM-8410 end of the cable should
be wired as shown in the tables below (one cable for the 100-pin connector and a
second cable for the 68-pin connector).
2.
For 42- and 84-spans configurations:
a.
Attach the trunk cable with a 100-pin male SCSI connector to the 100-pin female
SCSI connector labeled T1/E1 Trunks 1 to 25.
b.
Attach the trunk cable with a 68-pin male SCSI connector to the 68-pin female
SCSI connector labeled T1/E1 Trunks 26 to 42.
c.
For trunks 43 to 84, repeat steps 2.a and 2.b for the RTM-8410 housed in Slot #4.
3.
For 16-spans configuration: attach the trunk cable with a 100-pin male SCSI
connector to the 100-pin female SCSI connector labeled T1/E1 Trunks 1 to 16.
4.
Connect the other end of the trunk cables to the PBX/PSTN switch.
Note:
For RTM-8410 in Slot #4, ignore the trunk numbers printed on the two SCSI
connectors.
Hardware Installation Manual
E1/T1 Number
(68 to 84)
RTM-8410 in Slot #4
81
82
83
84
60
Mediant 3000
Tx Pins
Rx Pins
(Tip / Ring)
(Tip / Ring)
28 / 27
62 / 61
30 / 29
64 / 63
32 / 31
66 / 65
34 / 33
68 / 67
Document #: LTRT-94720