Ambient Temperature Sensor Calibration
Ambient Temperature Sensor Calibration
Test the sensor accuracy
Adjust dispenser reading
Compac Industries Ltd.
Calibrating the Ambient Temperature Sensor involves:
1.
Comparing the dispensers stated temperature to the actual
temperature.
2.
Adjusting the ambient temperature reading if it is found to be incorrect.
Using a calibrated temperature meter, determine the temperature of the
body of the dispenser Ambient temperature sensor.
Access the current dispenser ambient temperature reading (see page 29).
Adjust the dispenser's ambient temperature reading to match that of the
calibrated temperature meter (see page 29).
Page 70
Dispenser Calibration
www.compacngv.com