Plena Voice Alarm System | Software Manual | Action Programming
7

Action programming

7. 1

Overview

Use the Action programming window (see figure 7.1) to
program the actions of buttons, trigger inputs, etc. The
contents of the Action programming window depends on
the type of unit for which the actions are programmed.
figure 7. 1 : Action programming
Use the Unit drop-down list to select the unit for which
the actions are programmed:
Voice alarm controller (Controller)
Voice alarm router (Router)
Call station (Call station)
The buttons at the bottom of the Action programming
window are used to:
Save changes (Save)
Cancel changes (Cancel)
Close the window (Close)
7.2

Controller

7.2.1
Overview
Use the tabs to select the items for which the actions are
programmed:
Front panel (Front panel)
Emergency trigger inputs (EMG trigger)
Business trigger inputs (Business trigger)
Mic/line input (Mic/Line input)
Bosch Security Systems | 2005-10 | 9922 141 10384 en
7.2.2

Front panel

See figure 7.2 for an overview of the Front panel tab.
figure 7.2: Front panel
Proceed as follows:
1 Select the message that must be activated by the Alert
message button on the front panel of the voice alarm
controller from the Alert message drop-down list.
2 Select the message that must be activated by the
Alarm message button on the front panel of the voice
alarm controller from the Alarm message drop-down
list.
3 Select the message that must be activated by the
emergency button on the front panel of the voice
alarm controller from the EMG message drop-down
list.
4 Select the Main EMG mic priority level to set the
priority level for the microphone of the voice alarm
controller. Priorities 17, 18 and 19 can be set.
5 Select the RC 1EMG mic priority to set the priority
level for the microphone for remote control 1.
Priorities 17, 18 and 19 can be set.
6 Select the RC 2EMG mic priority to set the priority
level for the remote control 1. Priorities 17, 18 and 19
can be set.
7 Put a checkmark in the After EMG TRG release the
system remains in EMG state box to keep the system
in an emergency state until a reset. Otherwise the
system will stop the emergency state when the
trigger is released.
8 Click the Save button to save the changes.