Alcatel 1660SM Technical Handbook page 567

Stm 64 multiservice metro node
Hide thumbs Also See for 1660SM:
Table of Contents

Advertisement

QAUX interface:
It is provided as an additional TMN communication interface for message exchange between the NE and
a Remote OS station based on the use of a 2 Mbit/s proprietary protocol. It can be physically terminated
on a 2 Mbit/s auxiliary channel on the SERVICE card.
Q2 interface:
A mediation function interface is provided to connect the 1660SM to non–SDH network element
The RS–485 interface and the cable connector are provided on the CONGI card.
RE, RA, HK and leds interface:
RE consists of parallel I/O signals used for remote alarms that can be accessed on the CONGI card
RA is dedicated to send commands toward the rack to light up the relevant lamps.; the physical interface
is available on the CONGI card.
By pressing a push button is possible to store an alarm;
HK consist of parallel I/O signals used to handle housekeeping signals (for example alarms received from
Fans Subrack, open door etc.); In this way they can be supervised by Craft Terminal. The physical
interface is available on the CONGI card.
The Equipment Controller also drive the leds present on the front cover to display alarms or status
indication concerning the equipment ; for the meaning of the leds see para 2.4 on page 122.
By pressing a push button present on the PQ2/EQC front cover is possible to check the efficiency of the
leds.
ISSB bus:
It is an high performance bus supporting communication among the EC function, the SC function on the
MATRIX and Local Microprocessor present on the ATM board.
Other functions implemented are :
RESET PUSH–BUTTON used for EC reset.
RIBUS I/F
This block control the LED on the unit and is also used by the Shelf Controller on the MATRIX
to read the remote inventory data though the "RIBUS" .
RIBUS I/F is powered by the + 3.3 Vdc supply by CONGI boards.
REMOTE INVENTORY
It is the memory containing the board information, for identification purposes (see para. 3.17
on page 370 for details).
DC/DC CONVERTERS
This block converts the 48/60 V power supply to secondary voltages necessary for the circuits
on the board:
+3.3 V and + 2.5 V used to supply all the components in the board.
ED
02
3AL 91669 AA AA
674
565
/
674