Alcatel 1660SM Technical Handbook page 475

Stm 64 multiservice metro node
Hide thumbs Also See for 1660SM:
Table of Contents

Advertisement

Tx side (from LPC matrix to HPA ):
insertion of VC–m unequipped signal label
path trace insertion
BIP–2 insertion
REI and RDI insertion
LSUT is used to monitor unequipped path trails .
The main tasks of LPOM are :
trace identifier monitoring
RDI and REI recovering and deriving for performance primitives
signal label monitoring
VC–m BIP–2 errored block count
LPOM is used for performance monitoring purposes.
Other functions implemented are :
RIBUS I/F
This block is used to read/write from/to the "RIBUS" stream, to control the LED on the unit, to
release the Management–bus in case of power failure, and to use the remote inventory. RIBUS
I/F is powered by the + 3.3 Vdc supply by CONGI boards.
REMOTE INVENTORY
It is the memory containing the board information, for identification purposes (see para. 3.17
on page 370 for details).
M–BUS Driver
It drives the input–output gates of the Management–bus. These drivers can be disabled (by
the Bus–OFF signal) in case of power failure.
DC/DC CONVERTERS
This block converts the 48/60 V power supply to the following voltages:
3.3 V and 2.5 V used to supply all the components in the board.
–5.2 V to supply the optical module
The DC/DC converter is synchronized with a synchronization clock at 300 MHz (signal
Power–Sync, generated by G.A.) in order to avoid EMI problems.
ED
02
3AL 91669 AA AA
674
473
/
674

Advertisement

Table of Contents
loading

Table of Contents