Alcatel 1660SM Technical Handbook page 438

Stm 64 multiservice metro node
Hide thumbs Also See for 1660SM:
Table of Contents

Advertisement

Failure Condition: the Failure Condition FC
N.B.
SSF =Server Signal Fail, from upstream.
REI alarm detection (E): the REI
RAI alarm detection (A): the RAI
Sa6: the Sa6 bit is read for every 4 consecutive frames, to check the presence of the loopback2
command, when 4XSa6=1010, for 8 consecutive times.
Data Error detection (CRC–4): errors integrity check on the incoming data, according to CRC–4
procedure (Cyclic Redundancy Check), as defined in G.706. In case of errors, the alarm ERR
arised.
A* insertion: the A bit is
passed transparently in standard applications
set to '1' (*) when a failure condition (FC
set to '1' (*) when forced from the controller;
N.B.
(*): this option is enabled only in case of Leased Line applications.
E bit insertion (E): the outgoing E bit is set to 0 when
a failure condition (FC
errors (ERR
2M
the E insertion may be inhibited from controller, in this case E=1.
E=1 in other cases.
set to '0' (*) when Power Fail alarm (PWF) is active;
N.B.
(*): this option is enabled only in case of Leased Line applications.
Sa4* insertion: the bits Sa4 to Sa8 are passed transparently in standard applications,
Sa4 is set to '0' (*) when Power Fail alarm (PWF) is active, passed transparently otherwise.
N.B.
(*): this option is enabled only in case of Leased Line applications.
CRC–4 bits insertion: the CRC–4 on data is performed and the result is inserted on bits C1 to C4,
according to G.706.
Frame Word insertion (FW): the basic–frame and multi–frame alignment words are inserted on the
frame.
AIS insertion: a continuous bitstream of all 'ONES' is inserted, in case of occurrence of
force command from the controller;
a failure condition (FC
(*) a failure condition (FC
N.B.
(*): this option is enabled only in case of Leased Line applications.
ALARMS, STATUS AND COMMANDS CONVEYED FROM/TO CONTROLLER
Every alarm, status and errors counting results are reported to the controller, for monitoring purposes:
LOS, REI, RAI, FC, ERR(CRC–4), SSF detected either in upstream and in downstream signal
directions
N.B.
LOS = Loss of user Signal; SSF= upstream Server Signal Fail.
The controller sends the following commands, in order to enable the relevant functions:
LB–2, LB–RX, BF, MF, ForceA, InhibitE, etc.
N.B.
BF= Basic Frame; MF = Multi Frame.
ED
02
alarm is the "OR" of SSF
U
alarm is detected if E=0.
U
alarm is detected if active for 5 consecutive frames.
U
) is detected on signal from user (SY2Min);
2M
) are detected on data from user (SY2Min);
) on signal from SDH network (UP2Min);
U
) on signal from user (SY2Min).
2M
LOF
,
) is detected on signal from user (SY2Min);
2M
3AL 91669 AA AA
674
, AIS
, AUXP
alarms.
U
U
U
is
U
436
/
674

Advertisement

Table of Contents
loading

Table of Contents