[6]
Provides RIBUS device for power up status/configuration. Also, generation and monitoring of various
status and control signals are done through the ports of RIBUS.
[7]
Provides device to control and configure the two "DATA BACK PLANE INTERFACE" blocks through
the SPI bus and process DCC and AUX channels at the backplane.
[8]
Provide EEPROM for storing the configuration data.
[9]
Generates all the required voltages of 3.3V, 2.5V, 1.8V, 1.5V and 1.2V and provides circuitry for
monitoring these voltages.
[10] Provides timing circuitry, which includes 622 MHz VCXO and associated circuits for external clock
generation and PLL function.
[11] Provides one bicolour LED and a laser restart switch (the last drives both the optical interfaces on
board and on access card)
Other functions implemented are :
RIBUS I/F
This block is used to read/write from/to the "RIBUS" stream, to control the LED on the unit, to
release the Management–bus in case of power failure, and to use the remote inventory. RIBUS
I/F is powered by the + 3.3 Vdc supply by CONGI boards.
REMOTE INVENTORY
It is the memory containing the board information, for identification purposes (see para. 3.17
on page 370 for details).
ED
02
3AL 91669 AA AA
674