Alcatel 1660SM Technical Handbook page 480

Stm 64 multiservice metro node
Hide thumbs Also See for 1660SM:
Table of Contents

Advertisement

Other functions
Other functions implemented are:
RIBUS I/F
This block is used to read/write from/to the "RIBUS" stream, to control the LED on the unit, to
release the Management–bus in case of power failure, and to use the remote inventory.
REMOTE INVENTORY
It is the memory containing the board information, for identification purposes (see para. 3.17
on page 370 for details).
M–BUS Driver
It drives the input–output gates of the Management–bus. These drivers can be disabled (by the
Bus–OFF signal) in case of power failure.
DC/DC CONVERTERS
This block converts the –48/–60 V power supply to the following voltages:
3.3V and 2.5V used to supply all the components in the board
–5.2Vto supply the optical module
The DC/DC converter is synchronized with a synchronization clock at 300 MHz (signal
Power–Sync, generated by GA) in order to avoid EMI problems.
ED
02
3AL 91669 AA AA
674
478
/
674

Advertisement

Table of Contents
loading

Table of Contents