System Fans; System Fan Failure - Supermicro 6028R-E1CR12T User Manual

Storage system
Table of Contents

Advertisement

1
1
6-4

System Fans

Three 8-cm hot-swap fans provide the cooling for the system. It is very important
that the chassis top cover is properly installed and making a good seal in order for
the cooling air to circulate properly through the chassis and cool the components.

System Fan Failure

Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining
fans will ramp up to full speed and the overheat/fan fail LED on the control panel will
turn on. Replace any failed fan at your earliest convenience with the same type and
model (the system can continue to run with a failed fan). Remove the top chassis
cover while the system is still running to determine which of the fans has failed.
Caution: Except for short periods of time, do not operate the server without the chas-
sis cover in place. The cover must be in place to allow proper airflow and prevent
overheating.
Figure 6-2. Removing the Chassis Cover
1
2
Chapter 6: Advanced Chassis Setup
1
4
1
2
6-3
1
3
1
1

Hide quick links:

Advertisement

Table of Contents
loading