Supermicro 6028R-E1CR12T User Manual page 126

Storage system
Table of Contents

Advertisement

S
S
UPER
ERVER 6028R-E1CR12T User's Manual
Memory Correctable Error Threshold (Available when the item above-
Runtime Error Logging Support is set to Enabled)
Use this item to specify the threshold value for correctable memory-error logging,
which sets a limit on the maximum number of events that can be logged in the
memory-error log at a given time. The default setting is 10.
Erasing Settings
Erase Event Log
Select Yes to erase all error events in the SMBIOS (System Management BIOS)
log before an event logging is initialized at bootup. The options are No, Yes, Next
reset, and Yes, every reset.
When Log is Full
Select Erase Immediately to immediately erase all errors in the SMBIOS event log
when the event log is full. Select Do Nothing for the system to do nothing when
the SMBIOS event log is full. The options are Do Nothing and Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Disabled and Enabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between
1 to 255. The default setting is 1.
METW (Multiple Event Count Time Window)
This item is used to determine how long (in minutes) the multiple event counter
should wait before generating a new event log. Enter a number between 0 to 99.
The default setting is 60.
Note: Please reboot the system for the changes to take effect.
View SMBIOS Event Log
This item allows the user to view the event in the SMBIOS event log. The following
categories are displayed:
Date/Time/Error Code/Severity
7-40