Supermicro 6048R-E1CR36L User Manual

Supermicro 6048R-E1CR36L User Manual

Super storage system
Table of Contents

Advertisement

Quick Links

S
S
S
UPER
TORAGE
YSTEM
6048R-E1CR36L
USER'S MANUAL
1.0a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6048R-E1CR36L and is the answer not in the manual?

Questions and answers

Summary of Contents for Supermicro 6048R-E1CR36L

  • Page 1 UPER TORAGE YSTEM 6048R-E1CR36L USER’S MANUAL 1.0a...
  • Page 2 This manual is written for professional system integrators and PC technicians. It mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms provides information for the installation and use of the 6048R-E1CR36L.
  • Page 3 Preface UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10DRH-iT serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfig- uring the serverboard.
  • Page 4: Table Of Contents

    Table of Contents UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Table of Contents Chapter 3 System Interface Overview ......................3-1 Control Panel Buttons ..................3-1 Chapter 1 Introduction Reset ....................... 3-1 Overview ......................1-1 Power ......................3-1 Serverboard Features ..................1-2 Control Panel LEDs ..................
  • Page 5 Table of Contents UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Removing the Heatsink ................... 5-7 Event Logs ....................7-40 Installing Memory .................... 5-8 IPMI ....................... 7-42 Memory Support ....................5-8 Security Settings ................... 7-44 DIMM Installation .................... 5-8 Boot Settings ....................7-45 Adding PCI Expansion Cards ................5-11...
  • Page 6: Super Storages

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes...
  • Page 7: Overview

    Chapter 1 Introduction Overview The SuperStorageSystem 6048R-E1CR36L is comprised of two main subsystems: the SC847BE1C-R1K28LPB 4U chassis and the X10DRH-iT dual processor serverboard. Please refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com).
  • Page 8: Serverboard Features

    Onboard Graphics Graphics are provided by an onboard ASpeed AST 2400 BMC, which supports IPMI. The SuperStorageSystem 6048R-E1CR36L is built around the X10DRH-iT, a dual processor serverboard based on the Intel C612 chipset. Below are the main features of the X10DRH-iT. (See Figure 1-1 for a block diagram of the chipset.)
  • Page 9: Contacting Supermicro

    Chapter 1: Introduction UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. Figure 1-1. Intel C612 Chipset: 980 Rock Ave. System Block Diagram San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Note: This is a general block diagram. Please see Chapter 5 for details.
  • Page 10 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes...
  • Page 11: Chapter 2 Server Installation

    Unpacking the System You should inspect the box the 6048R-E1CR36L was shipped in and note if it was damaged in any way. If the server itself shows damage you should file a damage claim with the carrier who delivered it.
  • Page 12: Warnings And Precautions

    Chapter 2: Server Installation UPER TORAGE YSTEM 6048R-E1CR36L User's Manual • Rack Mounting Considerations This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). Ambient Operating Temperature • This product is not suitable for use with visual display work place devices If installed in a closed or multi-unit rack assembly, the ambient operating tempera- acccording to §2 of the the German Ordinance for Work with Visual Display Units.
  • Page 13: Rack Mounting Instructions

    Chapter 2: Server Installation UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Rack Mounting Instructions 3. Secure the rail to the chassis with four screws as illustrated. This section provides information on installing the chassis into a rack unit with the 4. Repeat steps 1-3 for the other inner rack rail.
  • Page 14: Installing The Inner Rails On The Chassis

    5. Repeat steps 1 through 4 above for the other inner rail. 6. Repeat steps 1-5 for the remaining outer rail. Note: chassis pictured may vary slightly from the 6048R-E1CR36L system chassis. 7. Pull out the middle rail until it locks to install the server.
  • Page 15 Figure 2-5. Installing into a Rack Notes: figures are for illustrative purposes only. Always install servers into racks from the bottom up. The chassis pictured may vary slightly from the 6048R-E1CR36L system chassis. Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing.
  • Page 16: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the drive carri- ers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components.
  • Page 17: Control Panel Leds

    Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally. Indicates all HDD channel activity. On the 6048R-E1CR36L, this LED indicates hard drive and/or DVD-ROM drive activity when flashing.
  • Page 18: Drive Carrier Leds

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Drive Carrier LEDs The chassis includes externally accessible SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. LED Color State Status Blue Solid On SAS drive installed Blue...
  • Page 19: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 20 Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Warnung ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ WICHTIGE SICHERHEITSHINWEISE ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬...
  • Page 21: Installation Instructions

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Installation Instructions Circuit Breaker Warning! Warning! This product relies on the building's installation for short-circuit (overcurrent) Read the installation instructions before connecting the system to the power source.
  • Page 22: Power Disconnection Warning

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual ¡Advertencia! 경고! El sistema debe ser disconnected de todas las fuentes de energía y del cable 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso 의존합니다.
  • Page 23: Equipment Installation

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door Warning! geschoold en gekwalificeerd personeel. Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 24: Battery Handling

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. !‫אזהרה‬ Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
  • Page 25: Redundant Power Supplies

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Redundant Power Supplies ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! Warning! This unit might have more than one power supply connection. All connections must 이...
  • Page 26: Comply With Local And National Electrical Codes

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Attention ‫מתח בפנל האחורי‬ L'équipement doit être installé conformément aux normes électriques nationales et locales. !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬...
  • Page 27: Hot Swap Fan Warning

    Chapter 4: Warning Statements for AC Systems UPER TORAGE YSTEM 6048R-E1CR36L User's Manual ¡Advertencia! 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 Al deshacerse por completo de este producto debe seguir todas las leyes y 物品太靠近風扇。 reglamentos nacionales. Warnung Attention Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis La mise au rebut ou le recyclage de ce produit sont généralement soumis à...
  • Page 28: Power Cable And Ac Adapter

    UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code power cables and AC adaptors. Using any other cables and adaptors could cause pour tous les autres appareils électriques que les produits désignés par Supermicro a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the seulement.
  • Page 29 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes 4-20...
  • Page 30: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter is provided as a reference and describes the data and power cable connections and add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
  • Page 31: Connecting Cables

    Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Connecting Cables Figure 5-1. Control Panel Header Pins Several cables need to be connected to the serverboard. These include the data cables for the peripherals and control panel and the power cables.
  • Page 32: Installing The Processor And Heatsink

    (Do not drop the CPU • on the socket. Do not move the Refer to the Supermicro web site for updates on CPU support. CPU horizontally or vertically and do not rub the CPU against any Installing an LGA2011 Processor pins of the socket, which may damage the CPU or the socket.)
  • Page 33: Installing A Passive Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Installing a Passive CPU Heatsink Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't 1.
  • Page 34: Installing Memory

    Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Installing Memory Processor & Memory Module Population Configuration For the memory to work properly, follow the tables below for correct installation. Caution: Exercise extreme care when installing or removing DIMM modules to prevent Processors and their Corresponding Memory Modules any possible damage.
  • Page 35: Adding Pci Expansion Cards

    1 CPU, 4 DIMMs 1 CPU, 6 or 8 DIMMs The 6048R-E1CR36L can accommodate up to five PCI expansion cards in the PCI expansion slots on the serverboard. Note that two of the slots are already populated with the IT mode disk controller card and the JBOD expansion card.
  • Page 36: Serverboard Details

    Blue: On Unit Identified on the X10DRH-iT. Onboard PWR LED Power On The 6048R-E1CR36L comes pre-installed with a Hardware RAID controller installed LEDM1 BMC Heartbeat LED Green: Blinking BMC Normal in PCI-E slot 2 and a JBOD expansion port installed in PCI-E slot 1.
  • Page 37: Connector Definitions

    Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Connector Definitions Power Fail LED ATX Power 24-pin Connector PWR Fail LED Pin Definitions Pin Definitions (JF1) The Power Fail LED connection is Pin# Definition Pin # Definition Pin# Definition located on pins 5 and 6 of JF1.
  • Page 38 Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Power On LED Power LED Internal Speaker Internal Buzzer (SP1) Pin Definitions (JF1) The Power On LED connector is lo- Pin Definition The internal speaker, located at SP1, Pin#...
  • Page 39 Note: UID can also be triggered via IPMI. For more information on IPMI, please to use the IPMB I C connection on Clock refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. your system. No Connection 5-18...
  • Page 40: Jumper Settings

    Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Jumper Settings TPM/Port 80 Header Pin Definitions Pin # Definition Pin # Definition Explanation of Jumpers TPM Header/Port 80 LCLK A Trusted Platform Module/Port 80 To modify the operation of the LFRAME# <(KEY)>...
  • Page 41 Chapter 5: Advanced Serverboard Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Watch Dog Enable/Disable LAN Enable/Disable GLAN Enable Jumper JWD1 controls the Watch Jumper Settings JPL1 enables or disables the Gb LAN Dog function. Watch Dog is a sys- Jumper Setting Definition ports on the serverboard.
  • Page 42: 5-10 Onboard Indicators

    Note: For more information on SATA HostRAID configuration, please refer to the ated with the connection speed LED. Intel SATA HostRAID User's Guide posted on our website at http://www.supermicro. com.. Dedicated IPMI LAN LEDs IPMI LAN Link LED (Left) &...
  • Page 43: 5-12 Installing Software

    YSTEM 6048R-E1CR36L User's Manual 5-12 Installing Software SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp. web-based interface in Windows and Linux operating systems. The program moni- supermicro.com.
  • Page 44: 5-13 Onboard Battery

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual 5-13 Onboard Battery Care must be taken to assure that the chassis cover is in place when the system is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed.
  • Page 45: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC847BE1C-R1K28LPB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 46: Control Panel

    Chapter 6: Advanced Chassis Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Removing the Chassis Cover Figure 6-1. Front and Rear Chassis Views Control Panel Hard Drives (24) Power Supplies (2) JBOD Expansion Ports I/O Ports Figure 6-2. Removing the Chassis Cover Removing the Chassis Cover Optional 2.5"...
  • Page 47: System Fans

    Chapter 6: Advanced Chassis Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual System Fans Figure 6-3. Replacing System Cooling Fans Seven 8-cm hot-swap chassis fans provide redundant cooling for the 6048R- E1CR36L. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
  • Page 48: Hard Drive Installation

    5. Replace the drive tray into the chassis. Make sure to close the drive tray handle to lock the drive tray into place (see Figure 6-5).. Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.supermicro.com/products/nfo/storage.cfm...
  • Page 49: Removing The Air Shroud

    Chapter 6: Advanced Chassis Setup UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Installing Optional Fixed Hard Drives Removing the Air Shroud Under most circumstances you will not need to remove the air shroud to perform Optional brackets for the SC847 chassis may be used to install either one 3.5" fixed any service on the system.
  • Page 50: Power Supply

    DC Power The AC power supplies may be removed and replaced with a DC power supply. The 6048R-E1CR36L has an 1280 watt redundant, hot-plug power supply consisting Replacing the AC Power Supply with a DC Power Supply of two power modules. Each power supply module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage.
  • Page 51 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Figure 6-9. JBOD Expansion Port JBOD OUT (downstream ports) Note: the use of two cables (8x SAS lanes) is recommended. 6-12...
  • Page 52: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.
  • Page 53: How To Start The Setup Utility

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall as 17:30:00. Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset Supermicro X10DRH-C/i the system while the BIOS is updating to avoid possible boot failure.
  • Page 54: Advanced Setup Configurations

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Advanced Setup Configurations Wait For 'F1' If Error Select Enabled to force the system to wait until the <F1> key is pressed if an error Use the arrow keys to select Advanced setup and press <Enter> to access the occurs.
  • Page 55 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS CPU Configuration illegal codes to overwhelm the processor to damage the system during an attack.  The options are Enable and Disable. (Refer to Intel's and Microsoft's websites for This submenu displays the following CPU information as detected by the BIOS. It more information.)
  • Page 56 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS AES-NI  CPU C State Control (Available when Power Technology is set to Custom) Select Enable to use the Intel Advanced Encryption Standard (AES) New Instruc- tions (NI) to ensure data security. The options are Enable and Disable.
  • Page 57 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Long Pwr (Power) Limit Ovrd (Override) Override BW_LIMIT_TF (BW_limit_tf ) Select Enable to support long-term power limit override. If this feature is disabled, This feature allows the user to turn off the "Override BW_Limit_TF (Time Frame)"...
  • Page 58 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS No PCIe Port Active ECO (Engineer Change Order) L0s Support This feature provides a work-around solution when there is no active PCI device When this item is set to Disable, IIO will not put its transmitter in the L0s state.
  • Page 59 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS PCI-E Port L1 Exit Latency dB), P5 (0.0/2.0 dB), P6 (0.0/2.5 dB), P7 (-6.0 /3.5 dB), P8 (-3.5/3.5 dB), and P9 (0.0/3.5 dB). Use this item to set the length of time required for the port specified by the user to complete the transition from L1 to L0.
  • Page 60 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS PCI-E Port L1 Exit Latency No PCIe Port Active ECO (Engineer Change Order) Use this item to set the length of time required for the port specified by the user This feature provides a work-around solution when there is no active PCI device to complete the transition from L1 to L0.
  • Page 61 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS dB), P5 (0.0/2.0 dB), P6 (0.0/2.5 dB), P7 (-6.0 /3.5 dB), P8 (-3.5/3.5 dB), and  Intel VT for Directed I/O (VT-d) P9 (0.0/3.5 dB). Intel VT for Directed I/O (VT-d) ®...
  • Page 62 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Link L1 Enable Set Throttling Mode Select Enable for Link L1 support to reduce power consumption. The options Throttling improves CPU reliability and reduces power consumption via automat- are Enable and Disable.
  • Page 63 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Patrol Scrub Interval Port 60/64 Emulation This feature allows you to decide how many hours the system should wait before Select Enabled to support I/O port 60h/64h emulation, which will provide complete the next complete patrol scrub is performed.
  • Page 64 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS SATA Configuration *If the item above "Configure SATA as" is set to IDE, the following items will  display: When this submenu is selected, AMI BIOS automatically detects the presence of...
  • Page 65 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS sSATA Port 0~ Port 3 Port 0~ Port 5 Select Enabled to enable a SATA port specified by the user. The options are Select Enabled to enable an sSATA port specified by the user. The options are Disabled and Enabled.
  • Page 66 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS  PCIe/PCI/PnP Configuration sSATA Port 0~ Port 3 Select Enabled to enable an sSATA port specified by the user. The options are PCI Latency Timer Disabled and Enabled. Use this item to configure the PCI latency timer for a device installed on a PCI bus.
  • Page 67 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Super IO Configuration MMIOHBase  Use this item to select the I/O base memory size according to memory-address Super IO Chip AST2400 mapping for the PCH chip. The base memory size must be between 4032G to ...
  • Page 68 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS VT-UTF8 Combo Key Support *If the item above set to Enabled, the following items will become available for configuration: Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled.
  • Page 69 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS SOL/COM2 Console Redirection Settings VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 Use this feature to specify how the host computer will exchange data with the client terminals.
  • Page 70 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS The following settings will be displayed: Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) Data Bits, Parity, Stop Bits The submenu allows the user to configure Console Redirection settings to support Out-of-Band Serial Port management.
  • Page 71 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS ACPI Settings 6. From the window that pops up, select "Enabled" and press <Enter>.  WHEA Support Select Enabled to support the Windows Hardware Error Architecture (WHEA) plat- form and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring.
  • Page 72: Event Logs

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Event Logs When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log This submenu allows the user to configure Event Log settings. when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full.
  • Page 73: Ipmi

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS IPMI BMC Network Configuration  The following items will be displayed: This submenu allows the user to configure Intelligent Platform Management Inter- • IPMI LAN Selection face (IPMI) settings. • IPMI Network Link Status...
  • Page 74: Security Settings

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Security Settings Boot Settings This submenu allows the user to configure the following security settings for the This submenu allows the user to configure Boot settings for this system: system. Boot Configuration...
  • Page 75: Save & Exit

    UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chapter 7: BIOS Delete Boot Option Discard Changes and Exit Select the target boot device to delete from the boot priority list. Select this item to exit from the BIOS setup without making any permanent changes to the system configuration, and reboot the computer.
  • Page 76 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes 7-48...
  • Page 77 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 78 UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Notes...
  • Page 79 Appendix B: System Specifications Appendix B System Specifications Processors Single or dual Intel® Xeon E5-2600 (v3/v4) Series processors Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C612 chipset BIOS 128 Mb AMI® SPI Flash ROM Memory Capacity Sixteen DIMM sockets supporting up to 2 TB of ECC LRDIMM (Load Reduced DIMM) or 1 TB of ECC RDIMM (Registered DIMM) DDR4-2400/2133/1866/1600...
  • Page 80 Appendix B: System Specifications UPER TORAGE YSTEM 6048R-E1CR36L User's Manual Chassis Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) SC847BE1C-R1K28LPB, 4U rackmount Dimensions: (WxHxD) 17.2 x 7 x 26 in. (437 x 178 x 660 mm)
  • Page 81 YSTEM 6048R-E1CR36L User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Table of Contents