4.3.2 Connection terminals of the power circuit
All terminal blcoks meet the requirements on EN 60947-7-1 (IEC 60947-7-1)
View of power supply and regenerative units
The terminals of a power supply and regenerative unit can be input or output dependent on the actual
operating status (power supply or regeneration). For the standardization of the view the line side is always
regarded as input and the DC voltage side is always regarded as output.
Picture 4.3.2 Description of the input terminals of the COMBIVERT R6
R6-S in E-housing
L1.2
L2.2
L3.2
Terminals
Description of terminals at KEB inverters
++, – –
DC voltage output with starting current limiting for loading the connected inverters; usable as input
for regenerative operation. If inverters with mains supply of type A1 or A2 (see 4.3.1) are available
in the DC bus, these may be switched to mains only after loading the DC bus. Note the maximum
DC link capacity or decoupling diodes !
L1.2, L2.2, L3.2
Mains input 3-phase coming from the commutation choke
Connection terminals of the power circuit
Name
Function
L1.2, L2.2, L3.2
3-phase mains connection to the commutation throttle
++, – –
DC voltage output with starting current limiting; Connection for the inverter, the connection
terminals are each internally connected in parallel.
Connection for shielding /earthing
Technical data of the connection terminals
Screw terminals (8mm internal hexagon)
Stay bolt M10
Stay bolt for ring thimble 10 mm
++
+
--
- -
+ +
Core cross-section [mm²]
min
35
Connection Terminals
R6-S in R and P-housing
L1
L1.2
L2.2
L3.2
L2
L1.2 L2.2 L3.2
max. tightening torque
max
Nm
95
20
25
++
+
--
lb inch
170
220
GB - 21