Figure 17 Ap150 Antenna Connection; Figure 18 Ap150 Connector Panel - Meru Networks ap150 Installation Manual

Hide thumbs Also See for ap150:
Table of Contents

Advertisement

Access Point 200
Antenna
Turn clockwise
to tighten
Figure 17: AP150 Antenna Connection
3.
Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown
in
Figure
18.
Caution!
Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be
plugged into the Console port.
(Reserved)
Power
Antenna 1
100/1000
inlet
Ethernet
Figure 18: AP150 Connector Panel
Vertical Mounting
To vertically mount an AP:
1.
Using the bracket holes as a template, mark the location on the wall for the two AP bracket
mounting screws. They are placed 4 ½ inches apart, center-to-center, one above the other. If you
are not using plastic wall anchors, you must center the mounting screws on a wall stud. If you do
not center the mounting screws on a wall stud, you must use plastic wall anchors.
(Reserved)
Reset
Console
(Push to restore
port
default settings)
Installing the Access Point
Antenna 2
Installing the AP150
31