DMX Values In-Depth (55-Channel Mode), continued
Ch.
Value
28
000 <--> 255 LED 1 - Red Intensity (0% <-> 100%)
29
000 <--> 255 LED 1 - Green Intensity (0% <-> 100%)
30
000 <--> 255 LED 1 - Blue Intensity (0% <-> 100%)
31
000 <--> 255 LED 1 - White Intensity (0% <-> 100%)
32
000 <--> 255 LED 2 - Red Intensity (0% <-> 100%)
33
000 <--> 255 LED 2 - Green Intensity (0% <-> 100%)
34
000 <--> 255 LED 2 - Blue Intensity (0% <-> 100%)
35
000 <--> 255 LED 2 - White Intensity (0% <-> 100%)
36
000 <--> 255 LED 3 - Red Intensity (0% <-> 100%)
37
000 <--> 255 LED 3 - Green Intensity (0% <-> 100%)
38
000 <--> 255 LED 3 - Blue Intensity (0% <-> 100%)
39
000 <--> 255 LED 3 - White Intensity (0% <-> 100%)
40
000 <--> 255 LED 4 - Red Intensity (0% <-> 100%)
41
000 <--> 255 LED 4 - Green Intensity (0% <-> 100%)
42
000 <--> 255 LED 4 - Blue Intensity (0% <-> 100%)
43
000 <--> 255 LED 4 - White Intensity (0% <-> 100%)
44
000 <--> 255 LED 5 - Red Intensity (0% <-> 100%)
45
000 <--> 255 LED 5 - Green Intensity (0% <-> 100%)
46
000 <--> 255 LED 5 - Blue Intensity (0% <-> 100%)
47
000 <--> 255 LED 5 - White Intensity (0% <-> 100%)
48
000 <--> 255 LED 6 - Red Intensity (0% <-> 100%)
49
000 <--> 255 LED 6 - Green Intensity (0% <-> 100%)
50
000 <--> 255 LED 6 - Blue Intensity (0% <-> 100%)
51
000 <--> 255 LED 6 - White Intensity (0% <-> 100%)
52
000 <--> 255 LED 7 - Red Intensity (0% <-> 100%)
53
000 <--> 255 LED 7 - Green Intensity (0% <-> 100%)
54
000 <--> 255 LED 7 - Blue Intensity (0% <-> 100%)
55
000 <--> 255 LED 7 - White Intensity (0% <-> 100%)

Troubleshooting

Symptom
Fixture Auto-Shut Off
Beam is Dim
No Light Output
No Power
Blown Fuse
Slow Movement
No Response to Audio Verify that the fixture is in "Sound Active" mode.
Fixture Not Respond-
ing / Responding
Erratically
Stiletto™ I7 User Manual - Rev. A
What It Does
Solution
Check the fan in the fixture. If it is stopped or moving slower than normal, the
unit may have shut itself off due to high heat. This is to protect the fixture from
overheating. Clear the fan of obstructions, or return the unit for service.
Check optical system and clean excess dust/grime.
Check to ensure fixture is operating under correct mode, IE sound active/auto/
DMX/Etc., if applicable.
Check fuse, AC cord and circuit for malfunction.
Check AC cord and circuit for damage, verify that moving parts are not re-
stricted and that unit's ventilation is not obstructed
Check that speed channels are set appropriately.
Make sure all connectors are seated properly and securely.
Use Only DMX Cables.
Install a Terminator.
Check all cables for defects.
Reset fixture(s).