Code
Panel display
(last 4 digits)
(Large LCD)
2F63
Hardware error
038A0002-2F63
Turn off printer, wait a
while, then turn it on again.
2F65
Hardware error
038A0002-2F65
Turn off printer, wait a
while, then turn it on again.
2F66
Hardware error
038A0002-2F66
Turn off printer, wait a
while, then turn it on again.
2F67
Hardware error
038A0002-2F67
Turn off printer, wait a
while, then turn it on again.
2F68
Hardware error
038A0002-2F68
Turn off printer, wait a
while, then turn it on again.
2F69
Hardware error
038A0002-2F69
Turn off printer, wait a
while, then turn it on again.
2F6A
Hardware error
038A0002-2F6A
Turn off printer, wait a
while, then turn it on again.
2F6B
Hardware error
038A0002-2F6B
Turn off printer, wait a
while, then turn it on again.
2F6C
Hardware error.
03130031-2F6C.
Turn off printer, wait, then
turn on again.
2F70
Hardware error.
03130031-2F70.
Turn off printer, wait, then
turn on again.
2F71
Hardware error.
03130031-2F71.
Turn off printer, wait, then
turn on again.
2F72
Hardware error.
03130031-2F72.
Turn off printer, wait, then
turn on again.
2F80
!Spectrophotometer sensor
is not mounted. Please check
if the sensor is mounted
properly and press OK.
2F81
! Spectrophotometer
Unit Calibration white tile
error.
Clean the tile then mount it
and press OK.
2F82
! Delivery guide of SP unit
is not mounted. Check if the
guide is mounted properly
and press OK.
2F83
!Backing plate error in the
spectrophotometer unit.
Clean the backing plate.
Install the backing plate to
the unit. Then press [OK].
2F85
! SP unit up and down cover
is open.
Close it and press OK
Panel display
Explanation/Detection sequence
(Small LCD)
The spectrophotometer up-down unit
upper detection sensor won't respond when
a predefined pulse is sent to the
spectrophotometer up-down unit motor.
When a predefined pulse is sent to the
spectrophotometer up-down unit motor,
the spectrophotometer up-down unit lower
detection sensor in spectrophotometer unit
won't respond.
Media dry fan won't return signals.
Embedded FlashROM read/ write error
Spectrophotometer EEPROM read/write
error
Write/read error at RAM check
Firmware update failed.
Initialization after power on of CPU at
spectrophotometer unit side failed.
Failed self-testing.
Indication at ink priming error in both
subtanks.
Call for Service.
Indication at ink priming error in the left
HW1 error
subtank.
03130031-2F71
Call for Service.
Indication at ink priming error in the right
HW1 error
subtank.
03130031-2F72
Spectrophotometer sensor won't return
signals.
After white calibration, the
spectrophotometer sensor returned a value
other than predetermined value.
While the spectrophotometer up-down unit
upper detection sensor and
spectrophotometer top cover open/closed
detection sensor are detecting, the interlock
switch remains OFF.
No signal retuned from backing plate.
The signal from the backing plate is
beyond threshold.
Spectrophotometer top cover open/closed
detection sensor won't respond.
Chapter 8
Remedial Action
1. Replace spectrophotometer up-
down unit motor.
2. Replace spectrophotometer up-
down unit upper detection sensor.
3. Re-install delivery guide.
4. Replace the spectrophotometer unit
PCB.
1. Replace spectrophotometer up-
down unit motor.
2. Replace spectrophotometer up-
down unit lower detection sensor.
3. Re-install delivery guide.
4. Replace the spectrophotometer unit
PCB.
1. Replace fan
2. Replace signal lines
3. Replace the spectrophotometer unit
PCB.
Replace the spectrophotometer unit
PCB.
Replace the spectrophotometer unit
PCB.
Replace the spectrophotometer unit
PCB.
1. Update firmware again
2. Replace the spectrophotometer unit
PCB.
Replace the spectrophotometer unit
PCB.
Replace the spectrophotometer unit
PCB.
For iPF6400 Series,
1. Replace both of the inktank units.
2. Replace the main controller PCB.
For iPF6400 Series,
1. Replace the left inktank unit.
2. Replace the main controller PCB.
For iPF6400 Series,
1. Replace the right subtank
2. Replace the main controller PCB.
1. Install Spectrophotometer sensor.
2. Check cables.
3. Replace spectrophotometer sensor.
4. Replace the spectrophotometer unit
PCB.
1. Clean white tile.
2. Mount white tile.
3. Replace spectrophotometer sensor.
1. Mount delivery guide.
2. Replace the spectrophotometer unit
PCB.
3. Replace spectrophotometer up-
down unit upper detection sensor.
1. Clean the backing plate.
2. Replace the spectrophotometer unit
PCB.
3. Replace the spectrophotometer
sensor.
1. Close spectrophotometer top cover.
2. Replace spectrophotometer top
cover open/closed detection sensor.
3. Replace the spectrophotometer unit
PCB.
8-31