Setting the Time Code
About the Time Code Display
An icon may appear next to the time code depending on the operation. Refer to the following table.
Icon
R
The time code mode is set to [Regen.].
94
P
The time code mode is set to [Preset] and the running mode is set to [Rec Run].
F
The time code mode is set to [Preset] and the running mode is set to [Free Run].
H
Time code display is on hold.
No icon
Time code during clip playback.
NOTES
NOTES
• The frames value of the time code runs from 0 to 23 (frame rate set to 23.98P or 24.00P), from 0 to 24 (frame
rate set to 25.00P or 50.00P), or from 0 to 29 (all other frame rates).
• When you are using interval recording, frame recording or slow motion recording, you cannot select the [Free
Run] running mode. Conversely, when you are using pre-recording mode, [Free Run] is set automatically and
cannot be changed.
• When you are using interval recording, frame recording or slow motion recording, the time code signal will not
be output from the SDI terminal or HDMI OUT terminal.
• When you mix drop frame and non-drop frame time codes, there might be a discontinuity in the time code at
the point where the recording starts.
• When you are using the [Free Run] running mode, the time code will continue running as long as the lithium
button battery has some charge left, even if you disconnect all other power sources.
• If you set an assignable button to [Time Code] (A 119), you can press the button to open the
[B # System Setup] menu.
Description