Description
Value Range
Default Value
ENH_FOVR_RANDOM_MAX_TIME_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
ENH_FOVR_RANDOM_MIN_TIME_n
Parameter Name Example
Value Format
Description
Value Range
Default Value
Document Version 2017-07
Specifies whether the retry timer is a fixed value or a random value
when the unit re-sends a REGISTER request when a failover failure
has occurred.
Note
•
This setting is available only when "ENH_FOVR_ENABLE_n" is
set to "Y".
•
For the fixed value setting, see REG_RTX_INTVL_n
(Page 275).
•
Y: Use a random value
•
N: Use a fixed value
N
ENH_FOVR_RANDOM_MAX_TIME_1,
ENH_FOVR_RANDOM_MAX_TIME_2, ...,
ENH_FOVR_RANDOM_MAX_TIME_8
INTEGER
Specifies the maximum value, in seconds, of the retry timer, which
determines the interval for re-sending REGISTER requests, when the
retry timer is set to be a random value.
Note
•
This setting is available only when "ENH_FOVR_ENABLE_n" is
set to "Y".
10–86400
15
ENH_FOVR_RANDOM_MIN_TIME_1,
ENH_FOVR_RANDOM_MIN_TIME_2, ...,
ENH_FOVR_RANDOM_MIN_TIME_8
INTEGER
Specifies the minimum value, in seconds, of the retry timer, which
determines the interval for re-sending REGISTER requests, when the
retry timer is set to be a random value.
Note
•
This setting is available only when "ENH_FOVR_ENABLE_n" is
set to "Y".
10–86400
10
5.3.22 SIP Settings
Administrator Guide