Alarm, Error And System Messages - Siemens SIMATIC ITP1000 Operating Instructions Manual

Industrial tablet pc
Hide thumbs Also See for SIMATIC ITP1000:
Table of Contents

Advertisement

6.6.8

Alarm, error and system messages

During startup (the boot process), the BIOS first performs a Power On Self Test (POST) and
checks whether certain functional units of the PC are operating error-free. The boot
sequence is immediately interrupted if critical errors occur.
BIOS initializes and tests further functional units if the POST does not return any errors. In
this startup phase, the graphics controller is initialized and any error messages are output to
the screen.
The error messages output by system BIOS are listed below. For information on error
messages output by the operating system or application programs, refer to the
corresponding manuals.
On-screen error messages
On-screen error message
Operating system not found
Keyboard controller error
SMART failure detected on HDD
CMOS battery failed
CMOS battery weak
Real-time clock has lost power
Keyboard error
PLD configuration failed
SIMATIC ITP1000
Operating Instructions, 05/2017, A5E37340160-AB
Technical specifications
6.7 Active Management Technology (AMT)
Meaning / tip
Possible causes:
No operating system installed
Incorrect active boot partition
Wrong boot drive settings in SETUP
Controller error.
Contact your technical support team.
Hard disk reports pending failure through
S.M.A.R.T.
CMOS battery is not connected.
CMOS battery is weak
The CMOS clock was operated without battery or
with a battery that was too weak, during battery
change, for example. Check the CMOS clock.
Function keys are defective
Programming of the PLC on the motherboard
has failed.
95