Install Wheelspace Thermocouples In Lower Half Second/Third Stage - GE MS-6001B Maintenance Instructions Manual

Gas turbines with dln-1 combustion systems gas only
Hide thumbs Also See for MS-6001B:
Table of Contents

Advertisement

Inspection and Maintenance — GEK 107048
seal strip with the notch facing in. Appropriately stake both seals. See Figures HGP-R.3 and
HGP-R.4.
4. Lift the nozzle and diaphragm segment on its hook fit and slide it along to its proper position.
Install nozzle segments from each horizontal joint to the center of the casing. For those nozzle
segments with thermocouple tubes protruding, insure that enough clearance is available to allow
the segments to be rolled in without damaging the tubes. Each segment and diaphragm weighs
approximately 35 pounds.
Note: Nozzle segment radial locating pins should be installed after each seg-
ment is moved into position.
5. Apply a light coat of anti-seize compound to all radial retaining pins.
Note: Prior to installing the radial retaining pin threaded access plugs, clean
the plug threads in the retaining pin hole. This will assist in making
reassembly of access plug easier.
6. Install the retaining pins as each nozzle segment is installed, where plugs are used to hold the re-
taining pins install the access plug so that it just bottoms on the retaining pin. Tighten the access
plug against the retaining pin and stake each plug at four (4) places on the edge of the threads.
7. Where pins are secured in place by holding plates, lockplates are to be used to lock the hex head
bolts.
Operation 3 — How to Install Wheelspace Thermocouples in Lower Half Second and Third
Stage Nozzle Segments
Note: The removable type thermocouples are located in segments 10 and 15
in the second stage nozzle and segments 11 and 14 in the third stage
nozzle. There are two thermocouples per segment.
Refer to the second and third stage nozzle arrangement drawings in the
Parts Lists and Drawings Volume of this Service Manual for details if
needed.
1. Prior to installing the wheelspace thermocouples, test the thermocouples to insure they are opera-
tional. This can be done by applying a small amount of heat to the tip and reading the output on
a temperature meter.
Note: The assembled length of the engaged portion of the thermocouple is
stamped on the turbine casing adjacent to the thermocouple tubing in-
stallation hole. This dimension may be used for reference when install-
ing the thermocouples. The reference dimension is from the top swage-
lok ferrell to the tip of the thermocouple.
2. Install the wheelspace thermocouples through the installation tubing in the turbine casing into
the second stage nozzle segment numbers 10 and 15 (two per segment).
3. Install the wheelspace thermocouples through the installation tubing in the turbine casing into
the third stage nozzle segment numbers 11 and 14 (two per segment).