5 Installation

Installation must be carried out by expert qualified personnel and in full compliance with current regulations.

5.1 Preliminary checks

Before installing, do the following:
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage;
• Fit tubing to drain away any water leaks which may cause oxidation;
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation
as compared to the other conductive parts inside;
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• Make sure there is a mechanical stop for opening and closing.
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the
current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
5.3 Cable list and minimum thickness
Connections
Control panel power supply 230V
Motor power supply 24V
Flashing light
Photocell transmitters
Photocell receivers
Accessories power supply
Control and safety devices
Antenna
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the
actual power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said products.
Type of cable
Type of cable
3G x 1,5 mm
3G x 1,5 mm
FROR CEI
2 x 0,5 mm
20-22
2 x 0,5 mm
CEI EN
4 x 0,5 mm
50267-2-1
2 x 0,5 mm
2 x 0,5 mm
RG58
Length of cable
10 < 20 m
2
2
3G x 2,5 mm
2
2
3G x 1,5 mm
2
2
2 x 1 mm
2
2
2 x 0.5 mm
2
2
4 x 0,5 mm
2
2
2 x 0,5 mm
2
2
2 x 0,5 mm
max. 10 m
Length of cable
20 < 30 m
2
3G x 4 mm
2
3G x 2,5 mm
2
2 x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 1 mm
2
2 x 0,5 mm