CAME AX5024 Installation Manual page 11

Automation for swing gates
Hide thumbs Also See for AX5024:
Table of Contents

Advertisement

5.8 Outward opening installation
A
(non-issued)
Supplementary bracket
TABLE 1
A
Opening
(mm)
90°
130
Weld pillar bracket to the non-issued supplementary bracket, while gate is open, then secure the brackets to the pillar, making sure the
"A" and "B" quotas shown in table 1 are met. Weld, or secure with proper screws, the gate bracket, making sure the "E" quota is met, as
shown in table 1. Finally, secure the gearmotor to the brackets with the issued screws and washers.
1
2
For AX5024 gearmotors, directly secure the standard issue bracket to the pillar without using the supplementary bracket, while taking
into account the measurements shown in table 2.
Finally, secure the gearmotor to the brackets with the issued screws and washers.
B
E
(mm)
(mm)
130
800
Extra bracket
Gate bracket
Pillar bracket
A
TABLE 2
A
Opening
(mm)
90°
200
Gate bracket
Pillar bracket
B
E
(mm)
(mm)
220
1100