Digital Projection
Lamps
The commands in the table below can be used with both projectors:
<command>
<operator>
lamp1.hours
?
lamp1.strikes
?
lamp1.serial
?
lamp1.status
?
lamp.power
= ?
INSIGHT 4K Series Protocol Guide
<values>
0 = Off
1 = Pre cooling
2 = Ignition
3 = Ignition confirm
4 = Enable communication
5 = Delay cooling
6 = Warm up eco mode
7 = Warm up
8 = Cool down no restrike
9 = Cool down ok restrike
10 = Normal
11 = Error
12 = Ignition retry
13 = Re strike delay
14 = Enable CSI
15 = Deferred shutdown
16 = Shutdown confirm
17 = Error shutdown
18 = Lamp warmup stage 1
19 = Lamp warmup stage 2
1 to 100 (integer)
LAMPS
Notes
lamp1.hours
The
command
returns the lamp hours in HH:MM
format.
Depending on the projector model,
lamp.power
the
command has a
different value range as follows:
•
For INSIGHT 4K Quad, the
range is between 80 and 100.
Any value lower than 80 will
be interpreted as 80 by the
projector.
•
For INSIGHT 4K Dual LED,
lamp power cannot be changed.
Rev A June 2016