9. Remove the nylon wire (F) – one screw at each end.
10. Prise off the front endblock cover (G).
11. Carefully slide off the rear endblock cover (H).
12. Unhook the corona wire (I) from the tension spring in the
rear endblock and from the screw in the front endblock
(do not remove the screw).
On reassembly:
• Do not touch the new corona wire with your bare
hands.
• Hook the new corona wire onto the rear endblock
first.
• Set the corona wire in the front endblock groove.
• Check the action of the tension spring after
installing the new wire.
• Rethread the nylon wire.
• To replace the corona unit, make sure that it is posi-
tioned correctly on the two springs. You will have
to push down quite hard to get it back in position.
While holding down the corona unit, put back the
transport guide plate.