6-3 CHARGE

6-3-1 Charge Corona Unit and Wire
1. Remove the operation panel (see section 6-1-4).
2. Remove the document table (see section 6-1-5).
3. Remove the front inner cover — 5 screws. See page 6-28.
4. Remove the front master unit guide rail (A) — 3 screws.
5. Remove the ozone duct (B) — 3 screws.
6. Remove the charge corona unit (C) – 2 screws.
7. Prise off the front endblock cover (D).
8. Carefully slide off the rear endblock cover (E).
9. Unhook the corona wire from the tension spring inside the
rear endblock cover.
10. Unhook the corona wire from the screw in the front end-
block cover.
Do not remove the screw.
On reassembly:
• Do not touch the new corona wire with your bare
hands.
• Hook the new corona wire onto the rear endblock first.
• Set the corona wire in the front endblock groove (F).
• After installing both ends of the new wire, test the
action of the tension spring.