6-4-4 L S D
1. Remove the operation panel (see section 6-1-4).
2. Remove the document table (see section 6-1-5).
3. Remove the front inner cover (see page 6-28).
4. Remove the LSD (A) — 1 connector, 2 screws.
Caution:
Do not touch the screws (B) on the LSD holder,
or the sensor on the new LSD will be misa-
ligned.
5. Make a test copy after reassembly. If the copy is not
centered, loosen the screws (B) and tap the LSD slightly to
one side (the adjustment is sensitive). Repeat step 5.