[ Manual Adjustment ]; Initial Setting (Manual) - Panasonic AJ-D400P Service Manual

Dvcpro series camera recorder
Table of Contents

Advertisement

4. When display shows "TOOL BOX NORMALIZING",
playback the colour bar portion of the alignment
tape and press the ENTER key.
Play back the DVCPRO MASTER TAPE. Then Press ENTER key.
5. Wait for the complain of USER DATA measure-
ment. When measurement is completed, the dis-
play shows the USER DATA and DEFAULT DATA
at the upper side of the display.
6. Compare the USER DATA and DEFAULT DATA,
and confirm that the difference is within ±0.01 as
shown in figure below.
7. The PC asks "NORMALIZING AGAIN?".
5MHz BPF
USER DATA
0.025150
DEFAULT DATA
0.025166
Normalizing Again? [(Y)/(N)]
Please Select (U)ser/(D)efault !!
8. If value is within the specification, press the "N"
key.
9. The PC asks "PLEASE SELECT (U)ser/(D)efault".
10. Press "U" to select the USER. This USER data
becomes as the DEFAULT data from the next op-
eration as shown in figure above.
11. If the value is not within specification, confirm the
connection of the adjustment system and quality of
the alignment tape, and perform the above steps 7
and 8 again.
12. ("NORMALIZING AGAIN?", press the "Y".)
13. If it is not improved after several times may be
something wrong with the EQ tool.
14. When performing the Auto Adjustment System
Normalization regularly under condition of the same
combination of the PC, A/D Board and EQ Tool, the
difference of USER DATA and DEFAULT DATA
should be within ±0.005
Tool Box Normalizing
Tool Box Normalizing
10MHz BPF
20MHz BPF
0.032330
0.030150
0.011832
0.032229
0.030103
0.011836

[ Manual Adjustment ]

Initial Setting (Manual)

<Note>
Following procedures are required when using spec-
trum analyzer instead of RF Adjustment Tool.
1. Connect the Camera Recorder, EVR and B.E.R.
counter as shown in figure.
Menu Setting
1. Open the operation panel.
2. Pressing [SHIFT], [+] and [-] buttons, set MENU
switch to SET position.
3. Set as follows:
PAGE : FUNCTION 3/5
PAGE : SERVICE ADJ.
4. After setting turn the menu OFF.
APF
ECU CONNECT
: EVR
CONCEAL
: OFF

Advertisement