Confidence Pb Envelope Level Adjustment - Panasonic AJ-D400P Service Manual

Dvcpro series camera recorder
Table of Contents

Advertisement

8-7. Rec. Curr. & Freq. Adj. (Auto)
BOARD
RF
PB ENV, HID R (50 W terminated)
TEST
ADJUST
VR400 (PB L), VR401 (PB R), EVR
MODE
PLAY, REC
TAPE
Blank Tape
M.EQ
Oscilloscope, Spectrum Analyzer
1. Open the MAIN MENU according to the same pro-
cedure as the PB Equalizer Adjustment.
2. Select 2. REC Adjustment in the MAIN MENU.
3. PC asks whether download the VT. Data from the
VTR or not.
4. Select [Y] so that the VT. Adjustment data is saved
in to the PC.
5. Press the F8 to select the AUTO.
6. Select 1. Adjust start in the sub menu.
7. Insert the alignment tape and playback the colour
bar portion according to the instruction on the dis-
play.
8. After memorizing the playback data, insert a blank
tape and start a recording according to the instruc-
tion on the display.
9. During the adjustment, don't touch the VT. and PC
adjustment system.
10. During the adjustment, audio error rate in not dis-
played.
11. Rewind the recorded tape which was recorded on
the blank tape and playback the recorded portion
according to the instruction on the display.
12. The error rate is measured and displayed.
13. Confirm that the data A and B are green colour.
8-8. Confidence PB Envelope Level
Adjustment
BOARD
RF
SPEC.
A = 100 ± 10mV
PB ENV, HSW (B.E.R. Counter)
TEST
(50 W terminated)
ADJUST
VR400 (PB L), VR401 (PB R)
INPUT
CAMERA Color Bar
MODE
REC
TAPE
Blank Tape
M.EQ
Oscilloscope
1. Place the unit in the confidence PB mode.
2. Adjust the VR400 and 401 so that the level A is
within specification.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj-d400pe

Table of Contents