Acura 3.5 RL Manual page 1192

1996 - 2004 years
Table of Contents

Advertisement

Driving Position Memory System (DPMS)
Power Mirror Control Unit Input Test (cont'd)
12P CONNECTOR "A"
BLU/GRN
LT GRN/RED
BLK/WHT
Cavity
Wire
Connect battery power
B3
BRN
to the B3 terminal, and
B4 terminal to the B9
YEL
B4
terminal momentarily.
Connect battery power
BRN
B3
to the B3 terminal, and
B12 terminal to the B9
B12
BLU
terminal momentarily.
Connect battery power
YEL
B2
to the B11 terminal, and
B2 terminal to the B9
B11
BRN
terminal momentarily.
Connect battery power
B10
BLU
to the B11 terminal, and
*
B10 terminal to the B9
BRN
B11
terminal momentarily.
Reconnect all connectors to the power mirror control unit.
Cavity
Wire
Ignition switch ON (II)
B8
RED/BLK
NOTE: Connect all
mirror control unit
BRN/WHT
B16
connectors.
Ignition switch ON (II)
B7
GRN
NOTE: Connect all
mirror control unit
connectors.
B16
BRN/WHT
Ignition switch ON (II)
NOTE: Connect all
B15
GRY
mirror control unit
connectors.
B16
BRN/WHT
Ignition switch ON (II)
GRN/WHT
NOTE: Connect all
B6
mirror control unit
connectors.
BRN/WHT
B16
Ignition switch ON (II)
B14
GRY
NOTE: Connect all
mirror control unit
BRN/WHT
connectors.
B16
BLU/ORN
RED/WHT
WHT/YEL
BLK
YEL
BLU
YEL/BLK
Test condition
Check the right power mirror
actuator operation:
The mirror should swing left.
Check the right power mirror
actuator operation:
The mirror should tilt down.
Check the left power mirror
actuator operation:
The mirror should swing left.
Check the left power mirror
actuator operation:
The mirror should tilt down.
Test condition
Check for voltage between the
terminals:
There should be about 5 V.
Check for voltage between the
terminals:
The voltage should change from
about 1 V to 3 V when the right
mirror swings from left to right.
Check for voltage between the
terminals:
The voltage should change from
about 1 V to 3 V when the right
mirror tilts from up to down.
Check for voltage between the
terminals:
The voltage should change from
about 1 V to 3 V when the left mir-
ror swings from right to left.
Check for voltage between the
terminals:
The voltage should change from
about 1 V to 3 V when the left mir-
ror tilts from up to down.
16P CONNECTOR "B"
RED/YEL
BLK
Test: Desired result
Test: Desired result
GRN
BRN
YEL
GRN/WHT
RED/BLK
YEL
BRN
GRY
BLU
BLU
GRY
Possible cause if result is not obtained
• Faulty right power mirror actuator
• An open in the wire
• Faulty right power mirror actuator
• An open in the wire
• Faulty left power mirror actuator
• An open in the wire
• Faulty left power mirror actuator
• An open in the wire
Possible cause if result is not obtained
• Faulty power mirror position
sensors
• An open in the wire
• Faulty right power mirror position
sensor
• An open in the wire
• Faulty right power mirror position
sensor
• An open in the wire
• Faulty left power mirror position
sensor
• An open in the wire
• Faulty left power mirror position
sensor
• An open in the wire
BRN/WHT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ka9

Table of Contents