not be shortened or extended. Low voltage cables with 3
m or 20 m length are available as optional accessories.
It is possible to let the low voltage cable cross the working
area. The low voltage cable must be stapled down or
buried, and the cutting height should be such that the
blades on the blade disc can never come in contact with
the low voltage cable.
Make sure the low voltage cable is laid along the ground
and secured with pegs. The cable must lie close to the
ground so as not to be cut before the grass roots have
grown over it.
The low voltage cable must never be stored in a coil or
under the charging station s base plate as this can
interfere with the signals from the charging station.
The power supply must be placed where it is well
ventilated and is not exposed to direct sunlight. The power
supply must be placed under a roof.
It is recommended to use an earth fault-breaker when
connecting the power supply to the wall socket.
If the power supply cannot be plugged directly into a wall
socket, do not under any circumstances mount the power
supply at a height where there is a risk it can be
12
submerged in water (at least 30 cm from the ground). It is
not permitted to place the power supply on the ground.
min 30 cm / 12"
min 30 cm / 12"
WARNING! No parts of the power supply must
under any circumstances be changed or tampered
with. The low voltage cable must not be shortened
or extended.
CAUTION! Place the low voltage cable so that the
blades on the blade disc can never come in
contact with it.
CAUTION! Use the plug to disconnect the
charging station, for instance before cleaning or
repairing the loop wire.
Installing and connecting the charging station
1. Position the charging station in a suitable spot.
2. Connect the low voltage cable to the charging station.
3. Connect the power supply's power cable to a
100-240V wall socket. If the power supply is connected
to an electrical socket outdoors, this must be approved
for outdoor use.
4. Attach the charging station to the ground using the
supplied screws. Ensure the screws are screwed all
the way down in the countersink.