10.4 Standards and Regulations

LEMCOM has been developed in accordance with the following standards:
-
EN61000-6-4/A1: 2007/2010
-
EN61000-6-2: 2005
Test standard
CISPR 16-2-3
CISPR 16-2-1
CISPR 14-1
CISPR 22
IEC / EN 61000-4-2
IEC/EN 61000-4-3
ENV 50204
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
NF EN 60068-2-6
(2008)
NF EN 62262
NF EN 60068-2-27
(2009)
/
/
COVAL - LMEIP-UK-D-1155UM0067
Description
Radiated disturbance measurements
Conducted disturbance measurements (power supply
access)
Conducted disturbance measurements
(communication and network access)
Electrostatic discharges (ESD)
Immunity to radiated interference
Electrical Fast Transient / Burst Immunity Test
Lightning and industrial surges
Immunity to conducted interference
Immunity to magnetic fields
Voltage dips, short interruptions and voltage
variations immunity tests'
Vibration resistance
IK07 test - Protection against mechanical impacts
Shock resistance
Humidity test
Temperature test
Technical specifications
Test result
Class A
Class A
Class A
Criterion B
Criterion A
Criterion A
Criterion B
Criterion B
Criterion A
Criterion A
Criterion A/B
5g, 10 to 150 Hz, 1 hr /
axes (x, y, z)
Impact energy: 2 joules,
500g weight, height:
40cm
10g, 11 ms, Half-Sine
Shock Pulse, 6 shocks
per axis (x, y, z)
+40°C, 95% RH, 24 hrs
72 hrs, 1°C / minute, 24
hrs at 0°C, +25°C and
+50°C