Regulations - Worcester Greenstar 8000 Life Installation And Maintenance Instructions Manual

Gas fired condensing combi boiler
Hide thumbs Also See for Greenstar 8000 Life:
Table of Contents

Advertisement

Regulations

H Combustion and corrosive materials
Do not store or use any combustible materials (paper,
thinners, paints etc.) inside or within the vicinity of the
appliance.
Chemically aggressive substances can corrode the
appliance and invalidate any warranty.
H Fitting and modification
Fitting the appliance and any controls to the appliance
may only be carried out by a competent engineer in
accordance with the current Gas Safety (Installation
and Use) Regulations.
Flue systems must not be modified in any way other
than as described in the fitting instructions. Any
misuse or unauthorised modifications to the
appliance, flue or associated components and
systems could invalidate the warranty. The
manufacturer accepts no liability arising from any such
actions, excluding statutory rights.
H General manual handling guidelines
▶ Only remove packaging at the time of the final
installation.
▶ Always use Health and Safety guidance for manual
handling of an appliance.
– Never lift or carry more than the safe guidance
limit on your own.
– Always use appropriate methods and equipment
when lifting/carrying an appliance.
▶ Never lift or carry packages by the shipping straps.
▶ During handling and unpacking, wear safety gloves.
▶ Dispose of packing materials appropriately.
H Important handling instructions
Care should be taken when transporting, lifting and
carrying the appliance.
▶ Use a means of transport suitable for handling
appliances (e.g. sack truck with strap, stair
climbing or step trolley).
▶ When handling appliances, secure them against a
fall.
▶ Let only trained personnel undertake the handling.
▶ The correct method for handling heavy objects
should be strictly observed, at all times.
6
2
Regulations
Installation regulations
Current Gas Safety (Installation and Use) Regulations:
All gas appliances must be installed by a competent, registered gas
engineer, such as a Gas Safe registered engineer or British Gas engineer
in accordance with the current regulations.
Failure to install appliances correctly could lead to prosecution.
The appliance must be installed in accordance with, and comply to, the
current:
▶ Gas Safety Regulations
▶ IET Regulations
▶ Building Regulations (England)
▶ Building Regulations (Wales)
▶ Building Standards (Scotland) (Consolidation)
▶ S.I. No. 183 and 292 - Energy Performance of Buildings Regulations
(Ireland; current version)
▶ Health and Safety Document 635 (The Electricity at Work
Regulations 1989) and any other local requirements
▶ EU Regulations No. 2017/1369 - Energy Labelling (as retained in UK
law and amended)
▶ EU Regulations No. 811/2013 - Energy Labelling (as retained in UK
law and amended)
Building Regulations Part L1A (Current version) - new dwellings
If the installation is in a new build property or it is a first time installation
in an existing property, the heating systems must conform to current
building regulations Part L1A.
The exception to this are single storey, open plan dwellings where the
living area is more than 70% of the total usable floor area. Then this type
of dwelling can be controlled as one zone.
An alternative would be individual electronically controlled TRVs.
For dwellings with a floor area over 150m
temperature control for each zone is required. It is best practice to fit
Thermostatic Radiator Valves (TRV's) to all radiators except the area
where the room thermostat is sited.
Building Regulations Part L1B (Current version) - existing dwellings
For appliance replacements on an existing system, it is not necessary to
zone the upstairs and downstairs separately, compliance with the zone
requirements can be achieved by a single room thermostat or
programmable room thermostat.
While the system is drained down, it is best practice to fit Thermostatic
Radiator Valves (TRV's) to all radiators except the area where the room
thermostat is sited.
Greenstar 8000 Life – 6720883865 (2021/11)
2
, separate time and

Hide quick links:

Advertisement

Table of Contents
loading