Factory settings
The LEMCOM provided to you has been configured with default settings that suit most applications.
Depending on the chosen model (LEMC60X or LEMC90X), LEMCOM is configured as follows:
L1/h1
L2/h2
Auto-blow
Auto-blow duration
ASC
DIAG ECO
Maximum bounces number
DIAG ECO analysis time (s)
Customer LED mode
Valves status mode
Recommendations
Default vacuum parameters may have to be adjusted to perfectly suit application requirements. If so,
it is recommended to respect the following conditions:
-
L2-h2 > L1
-
h1<L1
-
h2<L2
-
In case of rough or porous product handling, disable ASC to avoid vacuum pilot to turn ON
and OFF frequently.
INCORRECT SETTINGS INDICATION
If the recommendations given above are not respected when configuring a LEMCOM, the
MS led of the corresponding module will blink red.
COVAL - LMEIP-UK-D-1155UM0067
60% max. vacuum
Table 22 - Factory settings
i.e. regulation zone should be above the "object gripped" threshold
i.e. hysteresis should be lower than "object gripped" threshold
i.e. hysteresis should be lower than "regulation" threshold
LEMC60X...
35% / 10%
45% / 10%
500 ms
Vacuum characteristics
LEMC90X...
90% max. vacuum
65% / 10%
75% / 10%
OFF
ON
ON
2
1
BL1
MD1
37/42