Using Lemcom Webserver; Reset Lemcom's Ip Address; Lemcom Mac Address - Worcester Greenstar 36LXi User Instructions

Wall hung rsf gas-fired condensing combination boiler
Table of Contents

Advertisement

LEMCOM EtherNet/IP™ - User manual
6. Set new IP address and other network parameters
7. Master module restarts when "OK" button is pressed then LEMCOM Manager automatically
tries to reconnect to the LEMCOM (however, reconnection would fail if computer and
LEMCOM are not on the same network anymore).
The LEMCOM can now be connected to the factory or machine network.

6.2.2 Using LEMCOM webserver

Not implemented yet.

6.3 Reset LEMCOM's IP address

LEMCOM's IP address can be set back to its default value (10.3.182.163):
1. Unplug LEMCOM from the 24V DC power supply.
2. Press and hold the 'SET' button on the front panel of master LEMCOM.
3. Plug back in the power supply.
4. Release the button when MS led starts to blink.
IP address is now 10.3.182.163.

6.4 LEMCOM MAC address

Any LEMCOM master module can be identified on the ethernet network by its unique hardware
address, the MAC address.
The Coval OUI (Organizationally Unique Identifier) is 20:5A:00 so all LEMCOM MAC addresses
follow the format 20:5A:00:xx:xx:xx (where xx:xx:xx is an incremental and unique value).
The MAC address is written on the left side of the LEMCOM master module and can also be read
using LEMCOM Manager.
COVAL - LMEIP-UK-D-1155UM0067
Network configuration
SET
button
MS
led
17/42