Configuration Instance 160 - Worcester Greenstar 36LXi User Instructions

Wall hung rsf gas-fired condensing combination boiler
Table of Contents

Advertisement

LEMCOM EtherNet/IP™ - User manual

8.9.9 Configuration instance 160

Bit 7
Byte 0 : L1 gripping threshold for master module
Byte 1 : L1 gripping threshold for SM1
Bytes 0-15
...
Byte 15 : L1 gripping threshold for SM15
Byte 16 : h1 gripping hysteresis for master module
Byte 17 : h1 gripping hysteresis for SM1
Bytes 16-31
...
Byte 31 : h1 gripping hysteresis for SM15
Byte 32 : L2 regulation threshold for master module
Byte 33 : L2 regulation threshold for SM1
Bytes 32-47
...
Byte 47 : L2 regulation threshold for SM15
Byte 48 : h2 regulation hysteresis for master module
Byte 49 : h2 regulation hysteresis for SM1
Bytes 48-63
...
Byte 63 : h2 regulation hysteresis for SM15
Byte 64
ASC SM7
Byte 65
ASC SM15
DIAG ECO
Byte 66
SM7
DIAG ECO
Byte 67
SM15
Byte 68 : Maximum bounces number for master module
Byte 69 : Maximum bounces number for SM1
Bytes 68-83
...
Byte 83 : Maximum bounces number for SM15
Byte 84 : DIAG ECO analysis time (second) for master module
Byte 85 : DIAG ECO analysis time for SM1
Bytes 84-99
...
Byte 99 : DIAG ECO analysis time for SM15
AUTO
Byte 100
BLOW SM7
AUTO
Byte 101
BLOW
SM15
Byte 102 : Auto blow off duration (ms) for master module (1 to 9999 ms) – Least Significant Byte (LSB)
Byte 103 : Auto blow off duration (ms) for master module – Most Significant Byte (MSB)
Byte 104 : Auto blow off duration (ms) for SM1 – Least Significant Byte (LSB)
Bytes 102-
Byte 105 : Auto blow off duration (ms) for SM1 – Most Significant Byte (MSB)
133
...
Byte 132 : Auto blow off duration (ms) for SM15 – Least Significant Byte (LSB)
Byte 133 : Auto blow off duration (ms) for SM15 – Most Significant Byte (MSB)
Byte 134 : Valves status (in case of communication loss) for master module
Bytes 134-
Byte 135 : Valves status for SM1
...
149
Byte 149 : Valves status for SM15
Byte 150 : Customer LED mode (blue LED) for master module
Bytes 150-
Byte 151 : Customer LED mode for SM1
...
165
Byte 165 : Customer LED mode for SM15
COVAL - LMEIP-UK-D-1155UM0067
Bit 6
Bit 5
↓ ISLAND SETTINGS ↓
ASC SM6
ASC SM5
ASC SM14
ASC SM13
DIAG ECO
DIAG ECO
SM6
SM5
DIAG ECO
DIAG ECO
SM14
SM13
AUTO
AUTO
BLOW SM6
BLOW SM5
AUTO
AUTO
BLOW
BLOW
SM14
SM13
Table 21 - Data mapping - Configuration instance 160
Bit 4
Bit 3
ASC SM4
ASC SM3
ASC SM12
ASC SM11
DIAG ECO
DIAG ECO
SM4
SM3
DIAG ECO
DIAG ECO
SM12
SM11
AUTO
AUTO
BLOW SM4
BLOW SM3
AUTO
AUTO
BLOW
BLOW
SM12
SM11
EtherNet/IP™
Bit 2
Bit 1
ASC SM2
ASC SM1
ASC SM10
ASC SM9
DIAG ECO
DIAG ECO
SM2
SM1
DIAG ECO
DIAG ECO
SM10
SM9
AUTO
AUTO
BLOW SM2
BLOW SM1
AUTO
AUTO
BLOW
BLOW SM9
SM10
Bit 0
ASC
Master
Module
ASC SM8
DIAG ECO
Master
Module
DIAG ECO
SM8
AUTO
BLOW
Master
Module
AUTO
BLOW SM8