LEMCOM EtherNet/IP™ - User manual
RSLinx – Check LEMCOM visibility
Use RSLinx Classic to check whether the LEMCOM's IP address set is detected by the controller.
1. Start RSLinx Classic (Start menu > Rockwell Software > RSLinx > RSLinx Classic)
2. Click on the RSWho button:
3. Then open the path AB_ETHIP1, Ethernet (EtherNet/IP driver must be configured in
Communications > Configure drivers... menu). The LEMCOM can be seen with their IP
addresses:
Add LEMCOM module to an RSLogix 5000 project
Follow the steps below to add a LEMCOM module (or a LEMCOM island) to a project in RSLogix
5000.
1. In section I/O configuration, right-click on Ethernet then "New module..."
2. Type in "Lemcom" or "Coval" in the search box. Select the item that appears in the list then
click on "Create" (note that
COVAL - LMEIP-UK-D-1155UM0067
LEMCOM EDS file must be installed
EtherNet/IP™
prior to this).