4.1 Customer led (B1)

Functioning mode of the blue led can be configured according to customer needs using LEMCOM
Manager or LEMCOM Web Server.
The following modes are available:
MODE
Detailed functioning
ASC ENABLED + REGULATION ERROR :
BL 1
Led ON if ASC option is enabled / Blinking in case of regulation issue (permanent vacuum) / OFF
otherwise
ASC ENABLED:
BL 2
Led ON if ASC option is enabled / OFF otherwise
REGULATION IN PROGRESS :
BL 3
Led ON during regulation phase / OFF otherwise
REGULATION ERROR :
BL 4
Led blinking in case of regulation issue (permanent vacuum) / OFF otherwise
30M CYCLES PREVENTIVE MAINTENANCE :
BL 5
Led ON if Vacuum counter > 30 million cycles / OFF otherwise

4.2 Module Status indicator (MS)

Red LED
Green LED
OFF
OFF
OFF
Flashing
OFF
ON
Flashing
OFF
ON
OFF
Flashing
Flashing
COVAL - LMEIP-UK-D-1155UM0067
Table 3 - Customer led modes
Meaning
Not Powered: check power supply connection.
Standby: Device is not configured.
Operational: Device is configured and operating correctly.
Major Recoverable Fault: incorrect vacuum settings, low voltage error, high
temperature error.
Major Unrecoverable Fault: part lost error, firmware error.
Self-Test: Start-up phase in progress.
Table 4 - Module Status indicator meanings