Coval - Lmeip-Uk-D-1155Um0067; Configuration Assembly Instance - Worcester Greenstar 36LXi User Instructions

Wall hung rsf gas-fired condensing combination boiler
Table of Contents

Advertisement

LEMCOM EtherNet/IP™ - User manual

8.8.3 Configuration assembly instance

Assembly
Data size
Type
instance
(bytes)
160
CONFIG
166

COVAL - LMEIP-UK-D-1155UM0067

Description
L1 threshold (16 bytes)
h1 threshold (16 bytes)
L2 threshold (16 bytes)
h2 threshold (16 bytes)
ASC option (2 bytes)
DIAG_ECO option (2 bytes)
Max. bounces Nb (16 bytes)
DIAG ECO analysis time (16 bytes)
Auto blow (2 bytes)
Auto blow duration (32 bytes)
Valves status (16 bytes)
Customer led mode (16 bytes)
Table 12 - EtherNet/IP Configuration assembly instance
EtherNet/IP™
The assembly 160 is used to transfer the vacuum settings to all LEMCOM of an island (1 to 16 modules). The
parameters are sent to the master LEMCOM at PLC startup, when the communication with the unit is established.
Please note that, unlike LEMCOM Manager that warns user in case of incorrect parameters, the configuration
assembly lets the user sends any settings. That may lead to the apparition of warnings on the modules front panels
(for example: threshold or hysteresis set to 0).