Input Instance 140 - Worcester Greenstar 36LXi User Instructions

Wall hung rsf gas-fired condensing combination boiler
Table of Contents

Advertisement

LEMCOM EtherNet/IP™ - User manual

8.9.7 Input instance 140

Bit 7
Byte 0
-
Byte 1
-
SM7
Byte 2
present
SM15
Byte 3
present
Gripping
Byte 4
SM7
Gripping
Byte 5
SM15
ASC Status
Byte 6
SM7
ASC Status
Byte 7
SM15
Vacuum level – Master module – 0 to 99 % vacuum
Byte 8
Vacuum level – SM1 – 0 to 99 % vacuum
Byte 9
...
...
Vacuum level – SM15 – 0 to 99 % vacuum
Byte 23
Lost part on
Byte 24
SM7
Lost part on
Byte 25
SM15
ASC alarm
Byte 26
SM7
ASC alarm
Byte 27
SM15
30Mcycles
Byte 28
alarm SM7
30Mcycles
Byte 29
alarm
SM15
Temp alarm
Byte 30
SM7
Temp alarm
Byte 31
SM15
Power
Byte 32
alarm SM7
Power
Byte 33
alarm
SM15
COVAL - LMEIP-UK-D-1155UM0067
Bit 6
Bit 5
-
-
-
-
↓ ISLAND COMPOSITION ↓
SM6
SM5
present
present
SM14
SM13
present
present
↓ GRIPPING STATUS ↓
Gripping
Gripping
SM6
SM5
Gripping
Gripping
SM14
SM13
↓ REGULATION SYSTEM (ASC) STATUS ↓
ASC Status
ASC Status
SM6
SM5
ASC Status
ASC Status
SM14
SM13
↓ VACUUM LEVEL ↓
↓ LOST PART ALARM ↓
Lost part on
Lost part on
SM6
SM5
Lost part on
Lost part on
SM14
SM13
↓ REGULATION SYSTEM (ASC) ALARM ↓
ASC alarm
ASC alarm
SM6
SM5
ASC alarm
ASC alarm
SM14
SM13
↓ 30 MILLION CYCLES ALARM ↓
30Mcycles
30Mcycles
alarm SM6
alarm SM5
30Mcycles
30Mcycles
alarm
alarm
SM14
SM13
↓ TEMPERATURE ALARM ↓
Temp alarm
Temp alarm
SM6
SM5
Temp alarm
Temp alarm
SM14
SM13
↓ POWER SUPPLY ALARM ↓
Power
Power
alarm SM6
alarm SM5
Power
Power
alarm
alarm
SM14
SM13
Table 19 - Data mapping - Input instance 140
Bit 4
Bit 3
↓ HEARTBEAT ↓
-
-
↓ UNUSED ↓
-
-
SM4
SM3
present
present
SM12
SM11
present
present
Gripping
Gripping
SM4
SM3
Gripping
Gripping
SM12
SM11
ASC Status
ASC Status
SM4
SM3
ASC Status
ASC Status
SM12
SM11
Lost part on
Lost part on
SM4
SM3
Lost part on
Lost part on
SM12
SM11
ASC alarm
ASC alarm
SM4
SM3
ASC alarm
ASC alarm
SM12
SM11
30Mcycles
30Mcycles
alarm SM4
alarm SM3
30Mcycles
30Mcycles
alarm
alarm
SM12
SM11
Temp alarm
Temp alarm
SM4
SM3
Temp alarm
Temp alarm
SM12
SM11
Power
Power
alarm SM4
alarm SM3
Power
Power
alarm
alarm
SM12
SM11
EtherNet/IP™
Bit 2
Bit 1
-
-
-
-
SM2
SM1
present
present
SM10
SM9
present
present
Gripping
Gripping
SM2
SM1
Gripping
Gripping
SM10
SM9
ASC Status
ASC Status
SM2
SM1
ASC Status
ASC Status
SM10
SM9
Lost part on
Lost part on
SM2
SM1
Lost part on
Lost part on
SM10
SM9
ASC alarm
ASC alarm
SM2
SM1
ASC alarm
ASC alarm
SM10
SM9
30Mcycles
30Mcycles
alarm SM2
alarm SM1
30Mcycles
30Mcycles
alarm
alarm SM9
SM10
Temp alarm
Temp alarm
SM2
SM1
Temp alarm
Temp alarm
SM10
SM9
Power
Power
alarm SM2
alarm SM1
Power
Power
alarm
alarm SM9
SM10
Bit 0
Heartbeat
-
Master
module
present
SM8
present
Gripping
Master
Module
Gripping
SM8
ASC Status
Master
Module
ASC Status
SM8
Lost part on
Master
Module
Lost part on
SM8
ASC alarm
Master
Module
ASC alarm
SM8
30Mcycles
Master
Module
30Mcycles
alarm SM8
Temp alarm
Master
Module
Temp alarm
SM8
Power
alarm
Master
Module
Power
alarm SM8
32/42

Advertisement

Table of Contents
loading

Table of Contents