3.
Controlling the Power Supply to the
Fixing Heater
The temperature
of the fixing heater is
controlled by controlling the power supplied
to the fixing heater.
The power to the fixing heater is con-
trolled by controlling its phase.
The microprocessor on the DC controller
PCB controls the output timing of the fixing
heater driver signal (HTRD) so that power
suited to the target temperature of the fixing
heater may be supplied; this is to control the
phase of the power supplied
to the fixing
heater.
HTRD
c
I
Supply
power
I
to the
heater
1
"'i
1
7
1
'\
4.
Mrrecting
the Variation in the
Resistance of the Fixing Heater
The plane-shaped
heater used as the
fixing heater has production variations in its
resistance that would hinder proper execu-
tion of thermal control of the fixing heater.
To correct possible problems, the copier
compensates
for the variations
in terms of
seven settings of the resistance, whose val-
ues are read by a microprocessor.