Elin Induction Module Check - Siemens EH70650 Repair Instructions

Table of Contents

Advertisement

7.8

ELIN induction module check

This check must be performed with no power supplied.
Perform a visual inspection, thereby paying close attention to
burned components.
Verification of the IGBT's. The resistance values between the
legs of the IGBT's should be:
Check that the inductor construction screw has not been
stripped. If so, replace the screw, and if the thread problem is
on the fixed part, replace the complete module.
If, in spite of the fact that all the preceding checks were
negative, the induction zones associated with this board still
did not operate, replace the board.
206_58300000105199_ara_en_h – 15.03.a
A > 10 Kohm
B> 5 Kohm
Check that the fuse path is intact. If it is open, the complete
board must be replaced.