Connection to two phases with neutrals at a different voltage
In systems with a differentiated neutral, remove the pin, strip the ends
of the wires, and connect them to the corresponding terminals,
thereby making the power supply voltage of the appliance 230 VAC.
If the appliance is connected erroneously, the guaranty is void.
In the event that the appliance is erroneously connected at 400 V, the
Touch Control (TC) will show the U400 error on the display, and an
alarm tone will sound.
immediately and the connection checked in order to eliminate the
cause of the failure.
2.1.3
Installation
All indications in the installation manual must be respected. There is
additional information in the appliance manual and in the technical
documentation.
The appliance must not be started up if any damage due to transport
is observed.
206_58300000105199_ara_en_h – 15.03.a
The cooktop must be disconnected
2.1.4
Characteristics of Induction IV appliances
Pay special attention to the cooling inlets and outlets of induction
appliances.
For installation over an oven as well as over a cabinet, a separation of
20 mm from the wall or the back of the furniture must be left at the
rear of the appliance in order to allow correction ventilation.
In the event of installation over an oven, a distance of 4 mm between
the bottom part of the counter and the top part of the oven front must
be respected.
Air entry to the cooktop must not be obstructed.
If the appliance is installed in an enclosed piece of kitchen furniture,
the rear panel must be eliminated in order to provide correct
ventilation.