Siemens EH70650 Repair Instructions page 55

Table of Contents

Advertisement

Step P7: Parameter output
Some of these diagnostic and error- or state-counter functions write cells in
the EEPROM.
These functions can be disabled by an EEPROM-cell. The default value is
enabled.
In the "P7-menu" with each key the service-technician can read out a
parameter. In Twistpad control additionally the selection of cooking zones is
used. The parameter is shown as long as the corresponding key/cooking
zone is pressed/selected.
*)
six digits in Comfort-TC/Twistpad
four digits in Basic-TC
three digits in 3-fold TC (without units place)
**) in 3-fold TC's with only 6 keys except the power key the first and second key must be
pressed
together
***) The first key is the key on the left side. The second key is the next key right to the first
key. The
power key is left and mustn't be used. In Twistpad control there are also the selections of the
cooking-zones used and the directions for the cooking zones are like four keys that come
after
the key on the left side of the knob.
Sensor***
Indication
1
Ej. „S 1. 0 4"
2
Ej. „o 0 0 0"
3
Ej. „t 0 0 0"
4
Ej. „0 0 0 0"
5
Ej. „P 1 1 2"
6
Ej. „r 0 0 0"
7**
Ej. „E 1. 0 4"
8
„- - - -„
206_58300000105199_ara_en_h – 15.03.a
Description
Software version e.g. V1.04
Counter mains failure (400V)
Maximum selftemperature (conversion
required)
Hour counter * (6 digits in confort TC)
Part number
Counter power on
Version EEPROM e.g. Version 1.04
reserved
Step P8: Life-time test
This step is only for factory.
Step P9: Single deactivation of the operation time limit
To deactivate the operation-time-limit, in "P9-menu" any key except the
power key has to be pressed. While the key is pressed, every 7-segm.-
display shows "1". (e.g. "1111 ")
After 3sec., the service menu is stopped and the control goes into stand-by
mode. The keylock-LED is switched on.
Now, the control can be switched on (active mode) with the operation-time-
limit deactived. The keylock-LED remains on.
After switching off the control (stand-by mode) or after a reset, the operation-
time-limit is actived again. The keylock-LED switches off.
Seite 55 von 66